At MIDSCI™, we provide premium laboratory and scientific research equipment that meets the highest standards of accuracy, compliance, and durability. With over 40,000 products, including autoclaves, incubators, pipettors, centrifuges, and PCR Workstations, our equipment solutions are designed to support your lab and your life’s work.
Whether you’re working in cell culture, microbiology, or pharmaceutical development, MIDSCI™ offers everything from essential lab supplies and chemicals to advanced instruments, ensuring your research is efficient, safe, and repeatable.
Shop our full range of laboratory equipment now or contact your local Lab Consultant for personalized recommendations!
Looking for ways to save? Sign up for our newsletter to hear about upcoming offers!
Benchmark™ INCU-SHAKER™ 10 L
- Large platform 18 x 18 in., up to 5 x 2 L
- TOUCH screen control over time, speed and temperature
- Exceptional temperature uniformity
- Horizontally circular 19 mm orbit for aeration & mixing
- Instantly change flask clamps with MAGic Clamp™ accessories
- Optional shelf for Petri dishes, microplates, etc.
- Incu-Shaker 10 LR (Refrigerated) for temperatures down to RT -15°C
The Incu-Shaker™ 10 L provides digitally regulated temperature with orbital mixing optimized for culturing a variety of types of cells. The standard platform (included) features a non-slip rubber coated surface ideal for TC flasks, petri dishes, and staining trays. The convenient MAGic CLAMP™ Platform is also available for use with Erlenmeyer flasks and test tube racks. The unique, magnetic attachment method is the easiest way to instantly change between flask clamps of different sizes.
Features a Touch Screen with 3 Control Views:
- Standard View
- Advanced Temperature View
- Advanced Shaker View
Specifications
| IS-1010 | IS-1010R | |
| Temp. Range | Ambient + 5 to 60 °C | Ambient -15 to 60 °C |
| Temp. Uniformity | ±0.25% | ±0.25% |
| Temp. Accuracy | ±0.1% | ±0.1% |
| Shaking Speed Range | 30 to 300 rpm | 30 to300 rpm |
| Shaking Orbit | 19 mm | 19 mm |
| Platform Dimensions | 17.8 x 17.8 in. | 17.8 x 17.8 in. |
| Surrounding Operating Environmental Temp. Range | +4 to +65°C | +4 to +65°C |
| Exterior Dimensions: (W x D x H) | 20 x 26 x 19 in. | 20 x 31 x 22 in. |
| Weight | 120 lbs | 120 lbs |
| Electrical | 115 V (230 V available) | 115 V (230 V available) |
| Warranty | 2 year | 2 year |
Available Platforms for IS-1010 Incu-Shaker
| Item# | Description |
| IS-1010-PLAT | MAGic Clamp Universal |
| IS-1010-PSR | Universal Spring Platform |
| IS-1010-PMP | Microplate Platform, 6-Position |
Flask Clamp Capacities
| Item# | Description | Capacity |
| IS-50 | 50 mL Flask Clamp | 49 |
| IS-125 | 125 mL Flask Clamp | 36 |
| IS-250 | 250 mL Flask Clamp | 25 |
| IS-500 | 500 mL Flask Clamp | 16 |
| IS-1000 | 1000 mL Flask Clamp | 9 |
| IS-2000 | 2000 mL Flask Clamp | 5 |
| IS-1550 | Tube Rack (12 x 50 mL & 30 x 15 mL) | 4 |
| IS-T15 | Tube Rack (32 x 15 mL) | 8 |
| IS-T50 | Tube Rack (15 x 50 mL) | 8 |
| IS-T600 | Bottle rack (4 x 500/600 mL) | 2 |
Incu-Shaker™ - Stackable Shaking Incubator
Highlights:
- Stainless steel chamber provides premier temperature uniformity
- Proven reliable, maintenance-free Incu-Shaker™ motor drive system
- Bright, intuitive touch-screen controls
- Instantly change flask clamps with MAGic Clamp™ accessories
- Included pull-out adjustable shelf for static incubations
Premier Glass Door Laboratory Refrigerators
Premier Glass Door Laboratory Refrigerators are engineered to provide precise temperature control, dependable sample protection, and energyefficient performance for laboratory, research, and clinical environments.
Each unit is equipped with a microprocessorbased temperature controller and digital display, delivering superior temperature accuracy, rapid recovery, and reliable verification compared to traditional mechanical thermostats. An interior fandriven, forceddraft air circulation system ensures excellent temperature uniformity throughout the cabinet and quick stabilization after door openings.
To safeguard critical samples, Premier Laboratory Refrigerators include a comprehensive suite of audible and visual alarms that alert users to temperature deviations, power loss, and other critical conditions. The temperature display and alarm module operates independently of the microprocessor temperature controller, providing an added layer of security and reliability.
Premier refrigerators are available in a wide range of sizes and door configurations, with capacities ranging from 10 to 72 cubic feet, allowing laboratories to select the ideal unit for their storage needs.
Designed with sustainability in mind, these refrigerators utilize environmentally friendly natural hydrocarbon (HC) refrigerants that contain no hydrofluorocarbons. This significantly reduces globalwarming potential (GWP) while meeting EPA/SNAP mandates and complying with UL and ASHRAE guidelines.
Main Attributes
- Microprocessor temperature controller with digital display
- Superior temperature accuracy, stability, and recovery
- Fandriven forceddraft air circulation for uniform cooling
- Extensive audible and visual alarm system
- Independent monitoring and alarm module for added security
- Glass door design for easy inventory visibility
- Available in sizes from 10 to 72 cu. ft.
- Environmentally friendly HC refrigerants
- Compliant with EPA/SNAP, UL, and ASHRAE standards
2026 Centrifuge Promo!
MC-24R Bundle with COMBI-Rotor (C2417-R)
Bundle Includes:
One MC-24R Refrigerated Microcentrifuge (C2417-R-NR), 115V
& One COMBI-Rotor (C2417-RCMB)!
Add item # C2417-R to your cart for a bundle discount.
Use Promo Code: CEN26
Click here for more Benchmark Bundles
or see flyer for more details.
Free offer with purchase of designated items at listed price. Cannot be combined with other discounts or pricing.
Not valid on prior purchases. Special price applies only to the specified item; no substitutions.
Promo valid from 01/01/26 – 6/30/26. All terms and conditions apply.
MC-24R Refrigerated Microcentrifuge
- Included COMBI-Rotor™ accepts tubes and strips (lid included)
- Powerful refrigeration, as low as -20°C
- Touch operation
- Up to 16,800 xg!
- Status indicator light
Solid Door Built-In Vaccine Refrigerator
REFRIGERATION SYSTEM
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Please email tech@midsci.com or call 800-227-9997 to request a quote.
Airstream® Class II Type A2 Biosafety Cabinet, AR2 Models
The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet
Zero Volt Relay Contact to turn ON/OFF exhaust blower and signal the building alarm
Rocker Switches and Pressure Gauge
- Easy-to-use switches
- Displays filter loading status
- Manually adjustable UV timer
Adjustable UV Timer
- Easily adjustable to desired minutes or hours
- Prolongs UV lamp life, for not turning it ON overnight
One-Piece Interior Wall
- Double-layer side walls with negative pressure
- Easy-to-reach service fixture and outlets
- Large radius corner for easy cleaning
Dished Work Tray
- Contains spillage
- Angled edge for easy cleaning
- V-shaped grille to prevent blocking
Raised Ergonomic Armrest
- Helps prevent grille blocking
- Comfortable working posture
Removable Paper Catch
- Easy-to-clean
- Optional pre-filter can be fitted
Airflow Sensor
- Monitors real-time airflow for safety
- Alerts the user if airflow is insufficient
Energy-efficient DC ECM Blower
- The leading energy-efficient Class II Type A2 Biosafety Cabinet in the world with 70% energy savings compared to AC motor
- Stable airflow despite building voltage fluctuations & filter loading
- Standby mode to further reduce power consumption by 60%
ULPA Filter
- 10x Filtration efficiency of HEPA filter
- Creates ISO Class 3 work zone instead of industry-standard ISO Class 5
- Same 10 years filter life and replacement cost as HEPA filters
Dynamic Chamber™
- Blower plenum and side walls are surrounded by negative pressure
- Prevents contaminants from escaping outside
- Steel plenum with Isocide™ _coating, instead of flexible bag plenum, to prevent contamination leak
Angled Sash
- 10° angled front to optimize user comfort, reduce glare, and maximize reach into the work area
ISOCIDE™ Powder Coat
- Silver-ion-impregnated powder coat
- Inhibits microbial growth to improve safety
- Prevents the plenum from becoming a biohazard landfill
Standard Laboratory Refrigerator With Natural Refrigerants
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Shipping Weight: 200 Lbs.
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
- Sample Simulated Digital Temperature Display; .1° Resolution Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back
NEW! Haier solid-door pharmacy refrigerators!
Pre-order now to ensure you get yours.
New models (HYC-85FD, HYC-461FD, HYC-1031FD) will be in stock and available starting November 2024.
Haier Pharmacy Refrigerators
Used for storage of medicines, vaccines, reagents, biological products and other items that require a temperature between 2-8°C. Used in hospitals, pharmacies, pharmaceutical factories, clinics and laboratories etc.
- Energy Efficient: Each unit uses eco-friendly refrigerants: R290 (HYC-1031GD) and R600a (HYC-461GD) and offers low power consumption relative to performance
- Temperature Uniformity: Extends the shelf life of stored items and eliminates inconsistent results
- Insulation: Features polyurethane insulation
- Alarm Functions: Comes with multiple alarm functions, including audible/visual alerts for monitoring, and some include remote alarm contacts
- Cooling System: Uses hermetically sealed compressors and forced-air circulation for efficient cooling. Includes auto defrost
- Security: All models have security features, including a unique-key lock for safe storage
- Accessibility: Adjustable wire shelves are standard across all models to improve circulation and flexible storage
- Display and Controls: Integrated digital control panels with microprocessors are used in all models, allowing for precise temperature control and easy monitoring
- Low Noise Operation: All models are designed for quiet operation (35 – 43 dB(A))
Glass Door Freestanding Vaccine Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
| STABILITY² (CABINET AIR) | +/- 1.3°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.67 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 36 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Solid Door Freestanding Vaccine Refrigerator Certified to NSF/ANSI 456
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, PROPANE |
| CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
| STABILITY² (CABINET AIR) | +/- 1.3°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.5°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.67 KWH/DAY (315 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 42 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Please email tech@midsci.com or call 800-227-9997 to request a quote.
Labculture® Reliant G4 Class II Type A2 Biological Safety Cabinet
The new Labculture® Reliant G4 BSC is NSF-certified and available in three sash height openings: 8", 10", and 12" inches, with standby height that easily activates standby mode.
LR2 G4 ergonomic work zone is comprised of bright illumination using industry-leading LED combined with a raised, durable, stainless-steel armrest and large, recessed, spill-containing work tray devised for optimum work comfort.
Rocker Switches and Pressure Gauge
- New and improved controller interface
- Easy to use switches and displays filter loading status
- Manually adjustable UV timer
Energy-efficient LED
- Optimum work zone brightness
- Ideal light intensity of 1200 lux
- Saves energy and optimizes work comfort
Ergonomic Sash
- Available in 8”, 10”, and 12” sash openings
- Frameless, shatterproof, and UV-absorbing tempered glass
Tray support beams and holder
- Support beams for less vibration and holder for easy drain pan cleaning
Cabinet Construction
- Stainless steel side walls with side capture zones and negative pressure to optimize containment
- Single-piece work tray, spill retaining and easy to clean
Green Product
- Equipped with energy-efficient DC ECM that allows up to 70% energy savings vs AC motor
- Extremely low energy consumption
- Standby mode allows reduced power consumption by 80%
Items DW-86L729BPT and DW-86L829BPT have been discontinued.
See Haier Energy-Saving ULT Freezers for alternative options
or contact us for more information!
Haier -86°C ULT Freezers with Touchscreen
Advanced Hardware System
- 10 inch capacitive touch screen, state-of-art UI design coupled with sample management system to provide the optimal user experience.
- Advanced innovative design delivers excellent energy savings. The energy consumption is down to a single digit.
Optional IoT Software System
- Optional barcode scanner for simple, effortless and precise identification. Input and retrieve your samples with higher precision and efficiency.
- Check the real-time operating status via mobile phones or palmtop, simple and reliable.
- Instead of a manual system, the one-gun, one-code and one-key operation plus touch screen synchronization means you can access and retrieve your samples within seconds.
- Using Haier’s app and IoT technology the unit can be monitored and can self-diagnose faults, ensuring you are always aware of your unit’s status and able to make real-time and informed choices to protect your samples.
- Store hundreds of millions of scientific research and sample information in the cloud server.
Friendly Design
- Standard equipped with key lock, padlock and electromagnetic lock with optional fingerprint lock, providing multiple safeguards for sample safety.
- Special noise-reduction design plus super silent compressor technology and energy-saving fan, considerably lowers noise level.
- Ultra-low power consumption, down to less than 10kWh/day, ensuring a world leading energy saving performance.
- Double foaming for both inner and outer doors and five-layer sealing design and optimized super-thick VIP thermal insulation technology, extends temperature holdover time during power failure and increases insulation efficiency by 20%.
Web Content Viewer