At MIDSCI, we provide premium laboratory and scientific research equipment that meets the highest standards of accuracy, compliance, and durability. With over 40,000 products, including autoclaves, incubators, pipettors, centrifuges, and PCR Workstations, our equipment solutions are designed to support your lab and your life’s work.

Whether you’re working in cell culture, microbiology, or pharmaceutical development, MIDSCI offers everything from essential lab supplies and chemicals to advanced instruments, ensuring your research is efficient, safe, and repeatable.

Shop our full range of laboratory equipment now or contact your local Lab Consultant for personalized recommendations!

Looking for ways to save? Sign up for our newsletter to hear about upcoming offers!

|◀ 685 - 696 of 760 ▶|
View:

Gel Size: 10cm(W) x 15cm(L)
Buffer volume: 500ml

The MP-1015 is the ideal Multi-Purpose gel box for both extended high resolution, linear runs, and economical quick screens. The MP-1015 contains buffer recirculation ports for long runs requiring recirculation. The MP-1015 is constructed of 3/8" thick, cast acrylic, to withstand high voltages and temperature extremes. Unlike single piece molded units, the MP1015 will NOT warp or crack during extended use. This unit is designed to provide years of continuous operation.

Specifications:

Construction: Buffer tank is constructed of 3/8" thick, cast acrylic. Casting tray bottom is constructed of UV transmittance cast acrylic to allow viewing of the gel with a UV light source

Unit Dimensions: 7cm(H) x 16.5cm(W) x 30.5cm(L) Gel Dimensions: 10cm x 15cm

Shipping weight: 4.5 Lbs.

Distance between the electrodes: 27cm

Maximum Sample Capacity: 80 samples (4 combs, 20 samples each)

Buffer Capacity: 500ml

The maximum suggested applied voltage for the electrophoresis of DNA in agarose gels using the IB53000-MP1015 is 140 volts. In a 1% TBE gel, this translates into a run time of approx. 1 hour. Lower voltages can be used of course, and as a general rule a 70 volt run will take twice as long as a 140 volt run. Higher voltages can be used to decrease run time however, higher voltages can produce excessive heat and decrease sample resolution.

Complete System Includes:

  • Buffer Tank

  • Patented Vented Lid

  • IB53020 UVT Casting Tray

  • IB53030 Casting Fixture

  • Two, 2.0mm x 16-tooth combs

  • Power Cords

  • Bubble Level

  • Buffer ports

  • 4 year Warranty
Item#:
ASPCRELCTP3

Gel Size: 7cm(W) x 10cm(L)
Buffer volume: 250ml

Designed for Quick Screening and rapid, linear separation of nucleic acids. The QS710 requires 
minimal set-up and provides excellent band resolution and consistent lane-to-lane mobility 
for accurate results. A versatile system great for applications requiring quick screens such as 
fragment analysis and recombinant screening.

 

Specifications:

Construction: Buffer tank is constructed of 3/8" cast acrylic.

Casting Tray bottom is constructed of UV Transmittance cast acrylic to
allow viewing of gel with a UV light source

Unit Dimensions: 6.4cm(H) x 11.4cm(W) x 22.2cm(L)

Gel Dimensions: 7cm x 10cm

Distance between the electrodes = 19.3cm

Maximum sample capacity = 30 samples (2 combs / 15 samples ea)

Buffer Capacity = 250ml

Shipping weight = 3.0 lbs.

The maximum suggested applied voltage for the electrophoresis of DNA in agarose gels using the QS710 is 100 volts. In a 1% TBE gel, this translates into a run time of approx. 1 hour. Lower voltages may be used, of course, and as a general rule, a 50 volt setting will take twice as long as a 100 volt setting.

The suggested run parameters for the electrophoresis of RNA in agarose gels containing formaldehyde are 60 - 80 volts.

Complete System Includes:

  • Buffer Tank
  • Patented Vented Lid
  • IB51020 UVT Casting Tray
  • IB51025 Casting Fixture
  • Two, 1.5mm x 8-tooth combs
  • Power Cords
  • Bubble Level
  • 4 year warranty
Item#:
ASPCRELCTP2

The IBI "Lab-Pal" has been designed with the teaching lab in mind. The IB50000 utilizes  two glass slides, measuring 2" x 3", for casting the agarose. The small glass slide 
format is ideal for minimizing agarose use while still being an excellent teaching tool for students just learning about the separation of DNA molecules. 

Agarose slides can be cast days in advance and stored in buffer for later use. This helps maximize  class time

System Includes:

  • Vented lid
  • Dual casting fixture
  • 4 glass casting slides
  • (2) 1.5mm x 5-tooth combs
  • Bubble level
  • Power cords
  • 4 year warranty
Item#:
ASPCRELCTP1
Discontinued, Contact us for more options!

This model is being discontinued by the manufacturer. Only available while supplies last. 
Please contact us for availability or product recommendations. 

New, Gen 4 Units are available here!


Airstream® Reliant Class II Type A2 Biosafety Cabinets


Airstream® Reliant Class II Type A2 Biosafety Cabinets (AR2) is designed with energy efficiency, robustness, comfort and ergonomics. This cabinet uses ULPA (Ultra Low Penetration Air) filters which operate at a typical efficiency of 99.999% which is ten times the contamination protection over conventional HEPA filters. It also provides operator comfort through its raised arm rest which helps prevents grille blocking while providing operators with comfortable working position.
Item#:
ASESCONSG43FT

Upright Room Temperature Controlled Cabinet

 
The Compact Controlled Room Temperature Cabinets are purpose built for medical applications. These units feature a digital microprocessor temperature controller allowing for the precise temperature management necessary for medication storage at room temperature. A forced air directional refrigeration system provides superior temperature uniformity and recovery after door openings. 
A controlled temperature environment will ensure approved storage; preventing time wasted on unnecessary expense and product recalls. 
Freestanding models require 4” of clearance around back and sides of the unit for proper ventilation. Improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure.
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines.

  • Ul/c-ul Listed
  • Cycle Defrost
  • 115v, 60 Hz, 1/3 Hp, 2.3 Amps
  • Shipping Weight:  183 Lbs.
  • Microprocessor Temperature Controller
  • Digital Temperature Display
  • Audible and Visual  High and Low Temperature Alarms
  • 2 Probes; 1 in Air and 1 in Sample Bottle
  • Remote Alarm Contacts
  • Adjustable Operating Temperature Range:  68°f to 77°f (20°c to 25°c)
  • Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm

Templog Premier Manual Defrost Laboratory Freezer

 
TempLog Premier Manual Defrost Laboratory Freezers are purpose built for scientific and medical applications. Units feature a digital microprocessor temperature controller allowing for the precise temperature management necessary for critical samples and supplies. A manual defrost design prevents product damaging temperature spikes from defrost cycles.

Defrosting of the unit will need to be performed periodically to prevent severe ice build-up.

The Touch Screen temperature display and alarm module offers the latest in advanced temperature control and data logging. Offering industry-leading product security with a monitoring and alarm system that is 100% independent of the temperature controller.

Real-time sample simulated temperatures are constantly displayed, logged and supported by audible/visual high and low temperature alarms, along with power outage, sensor error and door ajar alarms, remote alarm dry contacts, a 4-20mA output and an access port are provided to simplify connections to existing facility monitoring systems. A USB port is provided for easy transfer as well as software updates.

  • Five Inner "Fast-freeze Compartments" With Doors for Temperature Maintenance
  • Four Fixed Shelves
  • Keyed Door Lock
  • Magnetic Door Gasket for Positive Seal
  • Stainless Steel Door Handle
  • Caster Platform (Adds 4" to Height)
  • Cfc-free Refrigerant (R404a), Foam Insulation and Packaging
  • Three Year Parts and Labor Warranty, Plus Additional Two Year Compressor Parts Warranty
  • Manual Defrost
  • 115v, 60 Hz, 6 Amps, 1/3 Hp
  • Ul/c-ul Listed
  • Microprocessor Temperature Controller
  • Adjustable Operating Temperature Range: -15°c to -25°c
  • Touch Screen Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
  • Password-protected Control Panel
  • Sample Simulated Digital Temperature Display; .1° Resolution, Adjustable Temperature Display in Celsius or Fahrenheit
  • Active Temperature Scale Bar Display
  • Resettable 1-point Min/max History
  • Digital 24-hour Temperature Chart
  • Temperature Data Logging
  • Usb Port for Data Transfer and Software Updates
  • Real-time Operational Display Clock
  • 4-20ma Output
  • Electronic Troubleshooting Guide
  • Electronic Qr Code to Access Owner’s Manual & Technical Support Contact Information
  • Adjustable Alarm Volume
  • Audible and Visual High/low Temperature Alarms
  • Sensor Error Alarm
  • Power Failure Alarm
  • Door Ajar Alarm
  • Low Battery Alarm
  • Operation Indicator
  • Alarm Validation (Audible, Visual, and Remote Alarm)
  • Alarm Mute With Ring Back
  • Remote Alarm Contacts

Standard Pharmacy Solid Door Refrigerator


Pharmacy Premier Series Refrigerators are Large Capacity Refrigerator Units for High Volume Pharmacies. Standard features include a microprocessor temperature controller and display for superior temperature control, verification, and recovery. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. An extensive package of audible and visual alarms is provided to protect critical samples and vaccines.
The temperature display and alarm module offers an array of robust security features with a monitoring and alarm system that is 100% independent of a microprocessor temperature controller for additional product security. 
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines.

  • Cycle Defrost
  • 115v, 60 Hz, 3 Amps, 1/5 Hp
  • Etl Listed
  • Shipping Weight: 227 Lbs.
  • Microprocessor Temperature Controller 
  • Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c) 
  • Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
  • Standard Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
  • Sample Simulated Digital Temperature Display; .1° Resolution 
  • Adjustable Temperature Display in Celsius or Fahrenheit 
  • Audible and Visual High/low-temperature Alarms 
  • 2 Probes; 1 in Air and 1 in Sample Bottle

Installation Service from DMX for ESCO Units
 
Please contact us for accurate pricing and further details.

800.227.9997 – tech@midsci.com  

Item#:
ASDMXINSTALL

Haier -86°C ULT Smart Freq Water-Cooled Freezers

  • Smart Frequency variable speed compressors improves temperature uniformity to ±3°C compared to ±6°C in standard freezers
  • Hydrocarbon (HC) refrigeration technology delivers fast temperature pull down and recovery
  • State of the art 10-inch touch screen panel
  • Noise-reduction design plus super silent compressor technology and energy-saving fan
  • ENERGY STAR certified – power consumption is 8.7 kWh per day
  • Equipped with key lock and padlock as a standard
Smart Frequency Freezers provide the ultimate temperature uniformity with the perfect combination of variable speed compressors and hydrocarbon (HC) refrigeration. Variable speed compressors will control the speed of the motor based on the heating or cooling load – substantially reducing energy without promising performance. With the hydrocarbon refrigeration technology, 50% less energy is used compared to the traditional CFC refrigerants found in standard freezers. The refrigerants do not contain fluorine or chlorine giving it a GWP value of just three, which is better for the environment. These units are applicable to many storage requirements found within blood storage facilities, hospitals, disease control, scientific research institutions, and biomedical engineering institutions.

Item#:
ASHAEIRWATER

Freestanding Pharmacy Countertop Controlled Freezer


The Premier Pharmacy Freestanding Undercounter Freezers feature a microprocessor temperature controller and display, allow for precise temperature control, verification and recovery versus mechanical style thermostats. Critical samples and supplies are security backed with an extensive package of audible and visual alarms
DISCLAIMER: Auto defrost freezers incorporate an electric heater installed on the evaporator that assist in the removal of the frost and ice. Although the heater helps speed up the frost and ice removal, it can raise the temperatures within the freezer 
The Freestanding models (“UCFS”) require 4” of clearance around back and sides of the unit for proper ventilation. Improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure.
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines. 
The acceptable temperature ranges for vaccine storage are 36°F to 46°F (or 2°C to 8°C) in the refrigerator and -58°F to 5°F (or -50°C and -15°C) in the freezer.

  • Auto Defrost
  • 115v, 60 Hz, 1 Amp,1/8 Hp
  • Ada Compliant
  • Ul/c-ul Listed
  • Shipping Weight:  106 Lbs.
  • Microprocessor Temperature Controller
  • Digital Temperature Display
  • Audible and Visual High and Low Temperature Alarms, With Battery Back Up
  • Remote Alarm Contacts
  • 2 Probes; 1 in Air and 1 in Glycol Bottle
  • Adjustable Operating Temperature Range: 5°f to -13°f (-15°c to -25°c)
  • Auto Defrost Cycle Every 6 Hours:
  • Max Air Temp in Empty Freezer: 4.34°c
  • Max Air Temp in Loaded Freezer: -2.89°c
  • Max Sample Temp in Empty Freezer: -4.76°c
  • Max Sample Temp in Loaded Freezer: -9.58°c
  • Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory
Item#:
ASFREPHCOUCF

Templog Premier Glass Door Laboratory Refrigerator


The TempLog Premier Glass Door Laboratory Refrigerators are purpose built for scientific and medical applications. Units feature a digital microprocessor temperature controller allowing for the precise temperature management necessary for critical samples and supplies. A forced air directional refrigeration system provides superior temperature uniformity and recovery after door openings. An automatic cycle-defrost design prevents product damaging temperature spikes.

The Touch Screen temperature display and alarm module offers the latest in advanced temperature control and data logging.
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines.

  • Cycle Defrost
  • 115v, 60 Hz, 3 Amps, 1/5 Hp
  • Shipping Weight: 258 Lbs.
  • Microprocessor Temperature Controller
  • Adjustable Operating Temperature Range: 1°c - 10°c 
  • Touch Screen Digital Temperature Display and Alarm Module
  • Password-protected Control Panel
  • Sample Simulated Digital Temperature Display; .1° Resolution, Adjustable Temperature Display in Celsius or Fahrenheit
  • Active Temperature Scale Bar Display
  • Resettable 1-point Min/max History
  • Digital 24-hour Temperature Chart
  • Temperature Data Logging
  • Usb Port for Data Transfer and Software Updates
  • Real-time Operational Display Clock
  • 4-20ma Output
  • Electronic Troubleshooting Guide
  • Electronic Qr Code to Access Owner’s Manual & Technical Support Contact Information
  • Adjustable Alarm Volume


Refrigerator and Freezer (-40°C Operation) Combination


The Premier Dual Temp Combination units feature separate microprocessor temperature controller allowing for precise temperature control, verification and recovery. An interior fan driven, forced-draft air circulation system provides excellent temperature uniformity and recovery after door openings. REFRIGERATORS ONLY
All models are equipped with digital temperature displays for convenient monitoring. Critical samples and supplies are security backed with an extensive package of audible and visual alarms. The freezer units feature either an automatic or manual defrost operating system. For manual defrost freezers, periodic manual defrosting is required.
This model requires 4” of clearance around back and sides of the unit for proper ventilation. Improper installation will void the warranty and will lead to temperature maintenance issues, overheating and possible failure.
Environmentally friendly, natural hydrocarbon (HC) refrigerants (not containing hydrofluorocarbons) vastly reduce global-warming potential (GWP) while meeting new EPA/SNAP mandates and UL, ASHRAE compliance guidelines.

  • Exterior Dimensions:23 3/4" W X 24"D X 65"H
  • Note: This Unit Must Have 4” Clearance on Sides and Back for Adequate Ventilation
  • Manual Defrost (Freezer); Cycle Defrost (Refrigerator)
  • 115v, 60 Hz
  • 2.2 Amps, 1/4 Hp (Freezer); 1.3 Amps, 1/6 Hp (Refrigerator)
  • Ul/c-ul Listed
  • Shipping Weight: 268 Lbs.
  • Microprocessor Temperature Controller
  • Digital Temperature Display
  • Audible and Visual High and Low Temperature Alarms
  • 2 Probes; 1 in Air and 1 in Sample Bottle
  • Remote Alarm Contacts
  • Adjustable Operating Temperature Range- Freezer:-37°c – -43°c; Refrigerator: 2°c to 8°c