S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Equipment
Get High-Quality Laboratory Equipment for Reliable Research
At MIDSCI™, we provide premium laboratory and scientific research equipment that meets the highest standards of accuracy, compliance, and durability. With products including autoclaves, incubators, pipettors, centrifuges, and PCR Workstations, our equipment solutions are designed to support your lab and your life’s work.
Whether you’re working in cell culture, microbiology, or pharmaceutical development, MIDSCI™ offers everything from essential lab supplies and chemicals to advanced instruments, ensuring your research is efficient, safe, and repeatable.
Shop our full range of laboratory equipment now or contact your local Lab Consultant for personalized recommendations!
Looking for ways to save? Sign up for our newsletter to hear about upcoming offers!
Solid Door Built-In Vaccine Refrigerator
REFRIGERATION SYSTEM
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Please email tech@midsci.com or call 800-227-9997 to request a quote.
Airstream® Class II Type A2 Biosafety Cabinet, AR2 Models
The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet
Zero Volt Relay Contact to turn ON/OFF exhaust blower and signal the building alarm
Rocker Switches and Pressure Gauge
- Easy-to-use switches
- Displays filter loading status
- Manually adjustable UV timer
Adjustable UV Timer
- Easily adjustable to desired minutes or hours
- Prolongs UV lamp life, for not turning it ON overnight
One-Piece Interior Wall
- Double-layer side walls with negative pressure
- Easy-to-reach service fixture and outlets
- Large radius corner for easy cleaning
Dished Work Tray
- Contains spillage
- Angled edge for easy cleaning
- V-shaped grille to prevent blocking
Raised Ergonomic Armrest
- Helps prevent grille blocking
- Comfortable working posture
Removable Paper Catch
- Easy-to-clean
- Optional pre-filter can be fitted
Airflow Sensor
- Monitors real-time airflow for safety
- Alerts the user if airflow is insufficient
Energy-efficient DC ECM Blower
- The leading energy-efficient Class II Type A2 Biosafety Cabinet in the world with 70% energy savings compared to AC motor
- Stable airflow despite building voltage fluctuations & filter loading
- Standby mode to further reduce power consumption by 60%
ULPA Filter
- 10x Filtration efficiency of HEPA filter
- Creates ISO Class 3 work zone instead of industry-standard ISO Class 5
- Same 10 years filter life and replacement cost as HEPA filters
Dynamic Chamber™
- Blower plenum and side walls are surrounded by negative pressure
- Prevents contaminants from escaping outside
- Steel plenum with Isocide™ _coating, instead of flexible bag plenum, to prevent contamination leak
Angled Sash
- 10° angled front to optimize user comfort, reduce glare, and maximize reach into the work area
ISOCIDE™ Powder Coat
- Silver-ion-impregnated powder coat
- Inhibits microbial growth to improve safety
- Prevents the plenum from becoming a biohazard landfill
Standard Laboratory Refrigerator With Natural Refrigerants
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Shipping Weight: 200 Lbs.
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
- Sample Simulated Digital Temperature Display; .1° Resolution Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back
NEW! Haier solid-door pharmacy refrigerators!
Pre-order now to ensure you get yours.
New models (HYC-85FD, HYC-461FD, HYC-1031FD) will be in stock and available starting November 2024.
Haier Pharmacy Refrigerators
Used for storage of medicines, vaccines, reagents, biological products and other items that require a temperature between 2-8°C. Used in hospitals, pharmacies, pharmaceutical factories, clinics and laboratories etc.
- Energy Efficient: Each unit uses eco-friendly refrigerants: R290 (HYC-1031GD) and R600a (HYC-461GD) and offers low power consumption relative to performance
- Temperature Uniformity: Extends the shelf life of stored items and eliminates inconsistent results
- Insulation: Features polyurethane insulation
- Alarm Functions: Comes with multiple alarm functions, including audible/visual alerts for monitoring, and some include remote alarm contacts
- Cooling System: Uses hermetically sealed compressors and forced-air circulation for efficient cooling. Includes auto defrost
- Security: All models have security features, including a unique-key lock for safe storage
- Accessibility: Adjustable wire shelves are standard across all models to improve circulation and flexible storage
- Display and Controls: Integrated digital control panels with microprocessors are used in all models, allowing for precise temperature control and easy monitoring
- Low Noise Operation: All models are designed for quiet operation (35 – 43 dB(A))
Glass Door Freestanding Vaccine Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
| STABILITY² (CABINET AIR) | +/- 1.3°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.67 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 36 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Solid Door Freestanding Vaccine Refrigerator Certified to NSF/ANSI 456
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, PROPANE |
| CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
| STABILITY² (CABINET AIR) | +/- 1.3°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.5°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.67 KWH/DAY (315 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 42 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Please email tech@midsci.com or call 800-227-9997 to request a quote.
Labculture® Reliant G4 Class II Type A2 Biological Safety Cabinet
The new Labculture® Reliant G4 BSC is NSF-certified and available in three sash height openings: 8", 10", and 12" inches, with standby height that easily activates standby mode.
LR2 G4 ergonomic work zone is comprised of bright illumination using industry-leading LED combined with a raised, durable, stainless-steel armrest and large, recessed, spill-containing work tray devised for optimum work comfort.
Rocker Switches and Pressure Gauge
- New and improved controller interface
- Easy to use switches and displays filter loading status
- Manually adjustable UV timer
Energy-efficient LED
- Optimum work zone brightness
- Ideal light intensity of 1200 lux
- Saves energy and optimizes work comfort
Ergonomic Sash
- Available in 8”, 10”, and 12” sash openings
- Frameless, shatterproof, and UV-absorbing tempered glass
Tray support beams and holder
- Support beams for less vibration and holder for easy drain pan cleaning
Cabinet Construction
- Stainless steel side walls with side capture zones and negative pressure to optimize containment
- Single-piece work tray, spill retaining and easy to clean
Green Product
- Equipped with energy-efficient DC ECM that allows up to 70% energy savings vs AC motor
- Extremely low energy consumption
- Standby mode allows reduced power consumption by 80%
Accuris IsoPure™ 96 & IsoPure™ Mini | Automated Extraction Systems
IsoPure™ 96
- Operates as a stand-alone system, or connects to PC for programming
- 8-position carousel for deep well sample plates
- Intuitive programming and operation on a user-friendly touchscreen
- Reliable and automated processing of up to 96 samples
The IsoPure™ 96 from Accuris Instruments is a high-throughput automated extraction system that improves the efficiency and reproducibility of magnetic bead extractions. Capable of processing up to 96 samples at one time, the instrument is easy to set up and program. Mixing, magnetic bead transfer, washing, and elution steps are performed automatically, saving valuable hands-on time. The complete purification process can be finished in as little as 10 minutes (depending on the reagent kit and the complexity of the program.)
IsoPure™ Mini
- Compact design takes up only 8 x 10 inches of bench space
- Intuitive programming on a user-friendly Android tablet app
- Higher yields and reproducibility than manual extraction methods
- Fast and reliable sample processing
The IsoPure™ Mini from Accuris Instruments is an extremely compact, automated extraction system that improves the efficiency and reproducibility of magnetic bead extractions. Capable of processing up to 16 samples at one time, the instrument is easy to set up and program. Mixing, magnetic bead transfer, washing, and elution steps are performed automatically, saving valuable hands-on time. The complete purification process can be finished in as little as 10 minutes (depending on the reagent kit and the complexity of the program.)
Specifications
| AP1096 | AP1016 | |
| Capacity / Sample Volume | 96 Samples / 50 uL to 1000 uL | 16 Samples / 50 uL to 1000 uL |
| Magnetic Bead Recovery Rate | >95% | >95% |
| Lysis Temperature Range | RT to 120°C | RT to 120°C |
| Elution Temperature Range | RT to 120°C | RT to 120°C |
| Display | 7.0 In. Color Screen | 4.3 In. Color Screen |
| Programming Control | Touch screen/mouse, or PC connection | Touch screen/mouse, or PC connection |
| Program Memory | 100 programs | 100 programs |
| Communication Ports | USB, Ethernet | USB, Ethernet |
| Contamination Control | UV Sterilization | UV Sterilization |
| Electrical Input | Universal 120 to 240VAC | Universal 120 to 240VAC |
| Dimensions | 22 x 24.5 x 19.7 In. 56 x 62 x 50 cm | 7.9 x 10.2 x 11.8 In. 20 x 26 x 30 cm |
Templog Premier Glass Door Chromatography Refrigerator
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°c - 10°c
- Touch Screen Digital Temperature Display and Alarm Module
- Password-protected Control Panel
- Sample Simulated Digital Temperature Display; .1° Resolution, Adjustable Temperature Display in Celsius or Fahrenheit
- Active Temperature Scale Bar Display
- Resettable 1-point Min/max History and Digital 24-hour Temperature Chart Temperature Data Logging
- Usb Port for Data Transfer and Software Updates
- Real-time Operational Display Clock
- 4-20ma Output
- Electronic Troubleshooting Guide
- Electronic Qr Code to Access Owner’s Manual & Technical Support Contact Info Adjustable Alarm Volume
- Audible and Visual High/low Temperature Alarms
SureAir™ PCR Workstation
- HEPA filter and UV light reduce cross-contamination during PCR preparation
- Compact, 22 x 16 In. footprint
- Cable port allows easy use of centrifuges, vortexers, and other instruments
- Includes pipette holder and shelf for storage of pipettes and tips
- Provides clean air within chamber to ISO 5 standards
The Benchmark™ SureAir™ PCR workstation is a compact, convenient way to reduce contamination concerns and provide a clean room environment at a fraction of the space and cost. The high-powered yet quiet internal fan produces laminar flow conditions without any installation into ductwork. The included HEPA filter purifies air within the chamber, meeting IS0 5 cleanliness standards, and filters 99.97% of particles 0.3 uM and larger. The double-hinged front panel provides ample workspace for convenient hand access and can be opened fully to allow placement of equipment inside.
The SureAir™ is designed to keep your workspace clean, easy-to-use, and organized. An included germicidal UVC light eliminates any stray DNA that may contaminate samples and is programmed to automatically shut off after 15 minutes. To protect users, the UVC light is only operational when the cover is closed and will shut off upon opening the cover. Ample lighting is provided by an energy-efficient LED light source. Up to 3 standard-sized pipettes are accommodated by the pipette holder integrated within the storage shelf. Pipette tips and small instruments can also be stored away from the main workspace when not in use. Power cables can easily be routed through the access port on the right side of the chamber.
ABS Standard Glass Door Laboratory Refrigerators
Standard Glass Door Laboratory Refrigerators deliver reliable, energyefficient cold storage designed specifically for laboratory environments. Built with ultralow energy consumption and natural refrigerants, these refrigerators provide a sustainable solution without compromising performance.
Equipped with microprocessor temperature control, this model ensures precise temperature monitoring and consistent cooling for sensitive samples and reagents. Essential safety features, including a keyed door lock, high- and low-temperature alarms, and remote alarm contacts, help protect valuable laboratory materials.
The durable, powdercoated steel exterior, transparent glass door, and adjustable shelves make organization simple and enhance workflow efficiency. Engineered for long-lasting performance, this refrigerator is ideal for research facilities, clinical labs, pharmaceuticals, and biotech applications.
Disclaimer
Refrigerator requires a minimum 2-inch clearance at the back and sides of unit for proper ventilation.
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R290, PROPANE |
| CONDENSER | FIN AND TUBE DESIGN, HIGH EFFICIENCY FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.0°C |
| STABILITY² (CABINET AIR) | +/- 1.1°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.7°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6.5 MIN. |
| ENERGY CONSUMPTION | 1.32 KWH/DAY |
| AVERAGE HEAT REJECTION | 2.21 KWH/DAY (315 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 49 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 30 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |