S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Equipment
Get High-Quality Laboratory Equipment for Reliable Research
At MIDSCI™, we provide premium laboratory and scientific research equipment that meets the highest standards of accuracy, compliance, and durability. With over 40,000 products, including autoclaves, incubators, pipettors, centrifuges, and PCR Workstations, our equipment solutions are designed to support your lab and your life’s work.
Whether you’re working in cell culture, microbiology, or pharmaceutical development, MIDSCI™ offers everything from essential lab supplies and chemicals to advanced instruments, ensuring your research is efficient, safe, and repeatable.
Shop our full range of laboratory equipment now or contact your local Lab Consultant for personalized recommendations!
Looking for ways to save? Sign up for our newsletter to hear about upcoming offers!
The Stovall Low Profile Roller is designed as a compact, space saving, non-dedicated instrument which performs multiple functions in the biological research laboratory. It operates on benchtops, in high humidity and CO2 incubators, high temperatures ovens (up to 65°C) and in refrigerated units (up to 0°C).
The low profile roller provides a convenient fit into laboratory incubators, ovens and refrigerated units without rearranging shelves or disturbing other materials. The variable speed control allows speeds of 2-38 rpm during use. With its industrial grade drive train and chemical resistant finishes this low profile roller will provide many years of great service to your lab!
Warranty: 1 year
Input Voltage: 90-240V
Roller Speed: 2-38 rpm
Max Load: 4L of liquid
Ambient Temp. Operation: 0°C to 65°C
Technical Data:
- Dimensions: 14-¼ " W x 15" D x 2 3/8" H
- Weight: 10.5 lbs ~ 4.8 kg
- Rollers: 1 1/8" diameter
- Speed: 3 - 30 rpm
Available platforms increases capacity.
ACCRL0001 |
Single Platform Stack |
ACCRL0002 |
Double Platform Stack |
ACCRLSR10 |
Single Roller |
ACCRLRN30 |
O-Ring Packet |
JULABO Refrigerated & Heating Circulators for heating and cooling are suitable for external temperature tasks and for temperature applications directly in the bath. A model from three different series' with different capacities can be selected. Powerful circulating pump systems and high heating and cooling capacities guarantee short heat-up and cool-down times. The inevitable dust accumulation that occurs in refrigeration systems is solved by means of an easily removed venting grill, which allows for easy cleaning. Depending on the model, the units are equipped with handles or castors for an easy transportation. All models have a drain tap on the front allowing the fluid to be drained easily. The compact assembly of each unit enables a space to be saved in the laboratory.
- Bright LED temperature display, resolution 0.1 °C
- Keypad for setpoint, switches automatically to the actual value
- PID1 temperature control
- Adjustable high temperature cut-out
- Low liquid level protection
- ATC 1-point calibration
- Timer function
Technical Specifications
Working temperature range
-35 to 150 °C
Temperature control
PID
Temperature stability
±0.03 °C
Display
LED
Display resolution
0.1 °C
Integrated programmer
not available
Heater capacity
1000 W (at 115V/60Hz)
Cooling capacity
20
0
-20
-30
°C
450
390
150
60
W
Refrigerant
R134a
Pump capacity
Pressure: 5.08 psi
Flow rate: 15 lpmBath opening / bath depth (W x L / D)
7.1 x 4.7 / 5.9 inches
Filling volume
8 Liters
Dimensions (W x L x H)
12.2 x 16.5 x 26 inches
Weight
79 lbs
Ambient temperature
5 to 40 °C
Classification according to DIN 12876-1
3 (FL)
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- UVP's patented 3UV Benchtop Transilluminator provides the selection of 365nm, 302nm and 254nm in one compact unit
- 2UV models offer 302nm and 365nm UV in one model
- Easily view gels under 365nm longwave UV for extended periods of time avoiding photonicking damage. Researchers can use the 302nm midrange to increase the fluorescence for photodocumentation. Shortwave 254nm UV is used to irradiate samples
- All Benchtop Transilluminator models are compact, lightweight units
- These 8-watt models provide a low cost alternative to the High Performance UV Transilluminators
- A variety of filter area work surface sizes are available
- Hinged, clear UV blocking cover, included with each transilluminator, is adjustable for access to the filter surface
- 2 year warranty
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
* Except M-10 which has standard ballast, 115V unit.
Intensity :
- Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information.
- Variable intensity settings-High/Medium/Low
- High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.
UV Source: Refer to the Part Numbers tab for specific wavelengths for each model
Watts: 8 watts, except M-10 which is 6 watts
Dimensions:
- 3UV Models: 11D x 14W x 5.4H in. (279 x 356 x 137mm)
- 2UV Models: 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- Single UV/Variable Intensity Models (Except M-10): 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- M-10: 7.25D x 10.25W x 4.5H in. (184 x 260 x 114mm)
- Height includes UV blocking cover (all models)
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
Options- Gel Tools
- Converter Plates
- BioImaging Systems
| 95-0457-01 (115V) | M-26E | Single | 302nm | 8 watt | 21x26cm |
| Single UV / Variable Intensity | |||||
| 95-0456-01 | M-15V | Variable | 302nm | 8 watt | 15x15cm |
| 95-0452-01 | M-20V | Variable | 302nm | 8 watt | 20x20cm |
| 95-0458-01 | M-26V | Variable | 302nm | 8 watt | 21x26cm |
| 95-0413-01 | M-26XV | Variable | 302 | 8 watt | 25x26cm |
| 2UV / Single Intensity | |||||
| 95-0449-01 | LM-20 | Single | 302/365nm | 8 watt | 20x20cm |
| 95-0459-01 | LM-26 | Single | 302/365nm | 8 watt | 21x26cm |
| 3UV / Single Intensity | |||||
| 95-0417-01 | LMS-20 | Single | 254/302/365nm | 8 watt | 20x20cm |
| 95-0414-01 | LMS-26 | Single | 254/302/365nm | 8 watt | 21x26cm |
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- UVP's patented 3UV Benchtop Transilluminator provides the selection of 365nm, 302nm and 254nm in one compact unit
- 2UV models offer 302nm and 365nm UV in one model
- Easily view gels under 365nm longwave UV for extended periods of time avoiding photonicking damage. Researchers can use the 302nm midrange to increase the fluorescence for photodocumentation. Shortwave 254nm UV is used to irradiate samples
- All Benchtop Transilluminator models are compact, lightweight units
- These 8-watt models provide a low cost alternative to the High Performance UV Transilluminators
- A variety of filter area work surface sizes are available
- Hinged, clear UV blocking cover, included with each transilluminator, is adjustable for access to the filter surface
- 2 year warranty
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
* Except M-10 which has standard ballast, 115V unit.
Intensity :
- Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information.
- Variable intensity settings-High/Medium/Low
- High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.
UV Source: Refer to the Part Numbers tab for specific wavelengths for each model
Watts: 8 watts, except M-10 which is 6 watts
Dimensions:
- 3UV Models: 11D x 14W x 5.4H in. (279 x 356 x 137mm)
- 2UV Models: 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- Single UV/Variable Intensity Models (Except M-10): 11D x 14W x 4.8H in. (279 x 356 x 122mm)
- M-10: 7.25D x 10.25W x 4.5H in. (184 x 260 x 114mm)
- Height includes UV blocking cover (all models)
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
Options- Gel Tools
- Converter Plates
- BioImaging Systems
| 95-0457-01 (115V) | M-26E | Single | 302nm | 8 watt | 21x26cm |
| Single UV / Variable Intensity | |||||
| 95-0456-01 | M-15V | Variable | 302nm | 8 watt | 15x15cm |
| 95-0452-01 | M-20V | Variable | 302nm | 8 watt | 20x20cm |
| 95-0458-01 | M-26V | Variable | 302nm | 8 watt | 21x26cm |
| 95-0413-01 | M-26XV | Variable | 302 | 8 watt | 25x26cm |
| 2UV / Single Intensity | |||||
| 95-0449-01 | LM-20 | Single | 302/365nm | 8 watt | 20x20cm |
| 95-0459-01 | LM-26 | Single | 302/365nm | 8 watt | 21x26cm |
| 3UV / Single Intensity | |||||
| 95-0417-01 | LMS-20 | Single | 254/302/365nm | 8 watt | 20x20cm |
| 95-0414-01 | LMS-26 | Single | 254/302/365nm | 8 watt | 21x26cm |
New electronic ballast and cutting-edge construction offers:
- Increased ultraviolet output and intensity
- No light flicker
- Wider intensity range with variable selection (select models)
- Fast lamp start up
- Universal power supply
- Reduced electrical consumption
- Longer tube life
- Lighter weight
- Improved gel visualization and gel documentation
- High performance 25-watt UV tubes for high fluorescence and sensitivity on stained gels
- Stainless steel cover frame provide an easy clean surface and reduces cross contamination of samples
- Uniform, brilliant back-lit fluorescence illumination is enhanced with UVP's unique background uniformity screen and UVG long-life filter
- Uniformity screen is available on units with midrange or longwave UV
- The transilluminator's powerful cooling fan maintains a low filter surface temperature to prevent sample damage and maintains a constant UV intensity
- The removable and adjustable protective UV blocking cover is included with each transilluminator
- Transilluminators carry a two-year warranty
- 2 year warranty
WARNING: Transilluminators are powerful sources of ultraviolet radiation which can cause serious damage to unprotected eyes and skin. Read the ultraviolet Caution Information before operating any transilluminators.
Intensity:- Select models offer single intensity other models include variable intensity. Refer to the part numbers tab for information.
- Variable intensity settings - High/Medium/Low
- High setting allows for UV excitation of fluorophores on gels for routine photography. Medium is excellent for viewing and quick single-band excision. Low setting allows for positioning and preparation of gels, excising multiple bands, and focusing for photography.
UV Source: 254nm, 302nm or 365nm
Watts: 25 watts
Dimensions: All Benchtop models : 13.25D x 19.13W x 5.63H in.
- Height includes UV blocking cover
- Weight: 21 lb. (9.6 kg)
Note about UV: UVP refers to its midrange UV products as 302nm. Other manufacturers may say 300nm, 310nm or 312nm. The spectral output of these units is the same as UVP's 302nm.
| Part Numbers | |||||
|---|---|---|---|---|---|
| 100-115V | 230V | Model | Intensity Style | Wavelength | Filter Size |
| Variable UV Intensity | |||||
| 95-0420-01 | 95-0420-02 | TFL-40V | Variable | 365nm | 20x40cm |
| 95-0423-01 | 95-0423-02 | TFM-20V | Variable | 302nm | 20x20cm |
| 95-0422-01 | 95-0422-02 | TFM-26V | Variable | 302nm | 21x26cm |
| 95-0424-01 | 95-0424-02 | TFM-30V | Variable | 302nm | 25x30cm |
| 95-0421-01 | 95-0421-02 | TFM-40V | Variable | 302nm | 20x40cm |
| 95-0427-01 | 95-0427-02 | TFS-20V | Variable | 254nm | 20x20cm |
| 95-0428-01 | 95-0428-02 | TFS-26V | Variable | 254nm | 21x26cm |
| 95-0429-01 | 95-0429-02 | TFS-30V | Variable | 254nm | 25x30cm |
| 95-0430-01 | 95-0430-02 | TFS-40V | Variable | 254nm | 20x40cm |
| 2UV | |||||
| 95-0431-01 | 95-0431-02 | TFML-20 | Single | 302/365nm | 20x20cm |
| 95-0432-01 | 95-0431-02 | TFML-30 | Single | 302/365nm | 25x30cm |
| 95-0425-01 | 95-0425-02 | TFML-26 | Single | 302/365nm | 21x26cm |
| 95-0426-01 | 95-0426-02 | TFML-40 | Single | 302/365nm | 20x40cm |
| Replacement Tubes | |||||
| Replacement Tube | 34-0073-01 | 25-watt, 254nm | |||
|---|---|---|---|---|---|
| Replacement Tube | 34-0072-01 | 25-watt, 302nm | |||
| Replacement Tube | 34-0060-01 | 25-watt, 365nm | |||
- Small footprint for benchtop use
- Preset and manual controls for ultraviolet or time exposures. Preset exposure delivers 120,000 microjoules or five minutes of exposure
- Microprocessor measures and control UV output, ensuring maximum energy efficiency
- Large LED display and touch panel which displays time or energy settings
- Window on the door allows viewing of the process yet blocks out the UV radiation
- Select from models with 302nm midrange UV, 365nm longwave UV or 254nm shortwave UV Interior: 12 deep x 10 wide x 5 high inches (305 x 254 x 127mm)
- Overhead UV supplies uniform UV
- Shortwave UV model is available with choice of door (CL-1000) or drawer (CX-2000) styles
- Built-in UV sensor is calibrated at the UVP factory to ensure accuracy and reliability
- Crosslinking for attaching nucleic acids to a membrane takes seconds as compared to oven baking
CL-1000 Dimensions: Exterior: 13.7 deep x 15.6 wide x 8.75 high inches (248 x 396 x 222mm)
CX-2000 Dimensions:
Exterior: 17.5"W x 15"D x 9.75"H (445 x 381 x 248mm)
Interior: 11.4"W x 11.3"D x 3.6"H (290 x 287 x 91mm)
Depth of sample tray 11.25 Width of sample tray 11.5
Sample surface to lamp approximately 3.5 in. (89mm)
1 year warranty
|
||||||||||||||||||||||||
Cutting-edge construction of UVP transilluminators includes an electronic ballast for increased stability and reduced power consumption. They also have a compact size to fit conveniently in small laboratory spaces. Benchtop UV transilluminators feature a fast lamp start-up with no light flicker. The FirstLight UV Illuminators offer high sensitivity and <5% coefficient of variance (CV) across the full filter area for consistency across the entire illuminated surface.
The FirstLight® UV Illuminator represents a unique highly uniform excitation source for quantitative fluorescent imaging in a wide range of genomic and proteomic applications:
- Electrophoretic separation and quantiation of 1D and 2D protein separations
- Solid phase immunoassay
- DNA quantitation
- RNA quantitation
Specifications: |
|
UV Source: |
UV Grid |
Wavelength: |
302 nm |
Intensity: |
Single |
UV Blocking Cover: |
Included |
Dimensions (WxDxH): |
14x11x5.63 inches |
Warranty: |
2 year |
- Lamps are lightweight.
- Models available include shortwave, longwave UV or a combination shortwave/longwave version
- Combination version comes with a snap-on wavelength selector for switching between wavelengths
- Use these lamps with the J-129 Lamp Stand (pictured) or the C-10 Cabinet
- 1 year warranty
Handheld Lamp Dimensions:
14.9"L x 3.2"W x 2.5"H
Lamp Stand Dimensions: 9.5"H x 13"L
Shortwave XX Series Lamps use ultraviolet radiation as a reliable and effective tool for sterilization and sanitation applications in hospitals, laboratories, pharmaceutical companies, and clinics. Work surfaces and equipment can become contaminated with bacteria which may be passed through the air or by hand infecting research projects and workers. In addition to bacteria, yeast, mold spores, germs, and viruses may also be present. Shortwave XX Series UV Lamps can kill up to 99% of these organisms. Decontaminate work surfaces with UV prior to PCR to reduce air-borne contamination during DNA sequencing. UV sterilization is particularly useful for temperature sensitive applications due to low operating lamp temperatures.
Shortwave Lamps can be used in an upward facing position for purifying the air or in a downward position for sanitizing work surfaces. Hanging the lamp (brackets provided) reduces the space required on laboratory benchtops. Longwave UV Bulbs (365nm) also available for all models. 1 year warranty
Dimensions
XX-15: 19.75"L x 6"W x 4.25"H
XX-20: 24"L x 6"W x 4.25"H
XX-40: 49.6"L x 6"W x 4.25"H
Exposure Stand: 20"L x 6"W x 13"H
Shaker Orbit LS Low Speed
- Economical analog control with easy-turn knobs
- 19 mm orbit for blotting, gel staining and general mixing
- Streamlined design
- Safe for cold room and incubator use
- 1 Year Warranty
The Orbit LS low speed shaker is a high quality, general purpose shaker with economical analog control.
Styled after the other models in the line, the Orbit LS features a streamlined, compact design with easy-access control panel. Electronic controls are utilized for setting speed and time. The knobs used for selecting parameters turn easily and are clearly marked with corresponding values.
A large orbit and low speed make the Orbit LS useful for staining and destaining gels, washing blots and general mixing. The shaker is supplied with a 30 x 30 cm stainles steel flat platform and non-slip rubber mat to keep plates, dishes and other sample containers in place.
Safe for use in temperature controlled environments, the small profile of this shaker makes it ideal for use in incubators such as the Labnet 311 and 611 series.Specifications:
| Speed range | 3 - 60 rpm | |
| 20 - 120 min (10 min inc.) or continuous | |
| Circular, 19 mm | |
| 11 lb/5 kg | |
| Ambient operating range | +4° to 70°C | |
| 10 x 12.6 x 6.3 in/ 25.5 x 32 x16 cm | |
| Weight | 14.5 lb/6.6 kg | |
| Electrical | 120V~, 60 Hz or 230V~, 50 Hz |
This item has been discontinued by the manufacturer.
See the new and improved Labnet™ 1001 Mini Plate Spinner Centrifuge for a great alternative.
Labnet™ Mini Plate Spinner Centrifuge
- Quickly spin down droplets and condensation
- Use before and after thermal cycling to increase PCR yield
- Accepts skirted, non-skirted and all standard PCR plates
- Less than 1/4 the size of most plate centrifuges
- 1 year warranty
Mini Plate Spinner Adapter Supports:
- 8 x 0.2 mL PCR Strips
- 12 x 0.2 mL PCR Strips
- 0.2 mL PCR Tubes
- 48 Well PCR Plates
Specifications
| Capacity | 2 PCR Plates |
| Rotor Speed | 2500 rpm |
| G Force | 500 x g |
| Rotor | Fixed Vertically |
| Dims (W x D x H) | 7.5 x 8.2 x 7.2 In. | 19 x 21 x 18.3 cm |
| Weight | 6 lbs | 3 kg |
| Electrical | 120V or 230V, 50-60 Hz |
StripSpin™ 12 Mini Centrifuge has been discontinued. A replacement model (C2248) can be found here.
StripSpin™ 12 Mini Centrifuge
- Unique rotor for 12-strip PCR tubes
- Also can be used with 8-strip and individual PCR tubes
- Starts and Stops with opening/closing the lid
- Tiny benchtop footprint and affordability
- Place a StripSpin at the bench, thermal cycler & water bath for convenience.
Specifications:
Speed: |
5,500 rpm / 2,000 xg |
|
4 x 12 position PCR strips |
|
|
Capacity: |
4 x 8 position PCR strips |
|
|
|
48 x 0.2ml PCR tubes |
Dimensions: |
5.5 x 7.9 x 4.4 in. |
|
|
(w x d x h) |
14 x 20 x 11.2 cm |
|
|
Weight: |
2.2 lbs. / 1 kg |
Electrical: |
Universal Voltage |
|
|
100-240V, 50-60 Hz, 300W |
|
Warranty: |
1 Year |
Web Content Viewer