S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Freezers and Refrigeration
Reliable and Precise Cold Storage for Your Lab
At MIDSCI™, we offer a full range of laboratory freezers and lab refrigerators engineered for accurate temperature control, superior reliability, and long-term protection of your most valuable samples.
From ultra-low temperature freezers to compact undercounter models and specialized medical refrigerators, our cold storage solutions meet the demands of life science, pharmaceutical, and research environments. Explore upright and chest freezers, blood bank refrigerators, vaccine storage units, and combo refrigerator/freezer systems, all designed for performance, safety, and compliance.
Contact us today to find the right cold storage solution to safeguard your most valuable samples, and sign up for our newsletter to keep up with new offers and promotions.
ABS Standard Glass Door Laboratory Refrigerators
Standard Glass Door Laboratory Refrigerators deliver reliable, energyefficient cold storage designed specifically for laboratory environments. Built with ultralow energy consumption and natural refrigerants, these refrigerators provide a sustainable solution without compromising performance.
Equipped with microprocessor temperature control, this model ensures precise temperature monitoring and consistent cooling for sensitive samples and reagents. Essential safety features, including a keyed door lock, high- and low-temperature alarms, and remote alarm contacts, help protect valuable laboratory materials.
The durable, powdercoated steel exterior, transparent glass door, and adjustable shelves make organization simple and enhance workflow efficiency. Engineered for long-lasting performance, this refrigerator is ideal for research facilities, clinical labs, pharmaceuticals, and biotech applications.
Disclaimer
Refrigerator requires a minimum 2-inch clearance at the back and sides of unit for proper ventilation.
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R290, PROPANE |
| CONDENSER | FIN AND TUBE DESIGN, HIGH EFFICIENCY FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.0°C |
| STABILITY² (CABINET AIR) | +/- 1.1°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.7°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6.5 MIN. |
| ENERGY CONSUMPTION | 1.32 KWH/DAY |
| AVERAGE HEAT REJECTION | 2.21 KWH/DAY (315 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 49 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 30 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Stainless Steel Built-In Vaccine Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
456 Pharmacy Solid Door Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R290, PROPANE |
| CONDENSER | FIN AND TUBE DESIGN, HIGH EFFICIENCY FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.0°C |
| STABILITY² (CABINET AIR) | +/- 1.1°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.7°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6.5 MIN. |
| ENERGY CONSUMPTION | 1.32 KWH/DAY |
| AVERAGE HEAT REJECTION | 2.21 KWH/DAY (315 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 49 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 30 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Premier Glass Door Chromatography Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Shipping Weight: 283 Lbs. Note: This Unit Requires Two (2) Outlets
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module
- Sample Simulated Digital Temperature Display; .1° Resolution
- Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back
Glass Door Built-in Vaccine Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Built-In Vaccine Refrigerator NSF/ANSI 456 Certified
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Standard Glass Door Chromatography Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Remote Alarm Contacts
- Adjustable Operating Temperature: 1°c to 10°c
Proudly made in the USA! Click here for more made in America products!
Need Cold Storage in a Hurry?
MIDSCI™ Delivers Fast with ABS | American BioTech Supply!
5-8 Days Shipping on Fast Track Freezers & Refrigerators
Check out the Laboratory FastTrack | Pharmacy FastTrack flyers for full details.
Items are subject to change without notice. Fast delivery options may end at any time and are dependent on stock availability and location.
While we strive to ensure the accuracy of all product descriptions and shipping timelines,
delivery times may vary based on factors such as order volume and shipping carrier performance.
MIDSCI™ and ABS|American BioTech Supply reserve the right to modify or discontinue promotions at their discretion.
All terms and conditions apply.
Standard Glass Door Laboratory Refrigerator
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Microprocessor Temperature Controller
- Digital Temperature Display
- Audible and Visual High and Low Temperature Alarms
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Remote Alarm Contacts
- Adjustable Operating Temperature: 1°C to 10°C
Proudly made in the USA! Click here for more made in America products!
Need Cold Storage in a Hurry?
MIDSCI™ Delivers Fast with ABS | American BioTech Supply!
5-8 Days Shipping on Fast Track Freezers & Refrigerators
Check out the Laboratory FastTrack | Pharmacy FastTrack flyers for full details.
Items are subject to change without notice. Fast delivery options may end at any time and are dependent on stock availability and location.
While we strive to ensure the accuracy of all product descriptions and shipping timelines,
delivery times may vary based on factors such as order volume and shipping carrier performance.
MIDSCI™ and ABS|American BioTech Supply reserve the right to modify or discontinue promotions at their discretion.
All terms and conditions apply.
Pharmacy Solid Door Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
- Temperature Monitor Device (Tmd) Complies With the Current Cdc Guidelines, With 3 Years Certification of Calibration, “buffered” Probe in the Product Simulated Solution, Min/max Memory. F/c Switchable, Field Installable, and Visual & Audible Temp Alarm
- Standard Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
- Sample Simulated Digital Temperature Display; .1° Resolution
- Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- 2 Probes; 1 in Air and 1 in Sample Bottle
Need Cold Storage in a Hurry?
MIDSCI™ Delivers Fast with ABS | American BioTech Supply!
5-8 Days Shipping on Fast Track Freezers & Refrigerators
Check out the Laboratory FastTrack | Pharmacy FastTrack flyers for full details.
Items are subject to change without notice. Fast delivery options may end at any time and are dependent on stock availability and location.
While we strive to ensure the accuracy of all product descriptions and shipping timelines,
delivery times may vary based on factors such as order volume and shipping carrier performance.
MIDSCI™ and ABS|American BioTech Supply reserve the right to modify or discontinue promotions at their discretion.
All terms and conditions apply.
Pharmacy Stainless Steel Laboratory Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 6 Amps, 3/8 Hp
- Etl Listed
- Shipping Weight: 295 Lbs.
- Microprocessor Temperature Controller
- Digital Temperature Display With Battery Back-up to Support Temperature Monitoring and Alarms
- Audible and Visual High and Low Temperature Alarms
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Adjustable Operating Temperature Range: 36°f to 46°f (2°c to 8°c)
Need Cold Storage in a Hurry?
MIDSCI™ Delivers Fast with ABS | American BioTech Supply!
5-8 Days Shipping on Fast Track Freezers & Refrigerators
Check out the Laboratory FastTrack | Pharmacy FastTrack flyers for full details.
Items are subject to change without notice. Fast delivery options may end at any time and are dependent on stock availability and location.
While we strive to ensure the accuracy of all product descriptions and shipping timelines,
delivery times may vary based on factors such as order volume and shipping carrier performance.
MIDSCI™ and ABS|American BioTech Supply reserve the right to modify or discontinue promotions at their discretion.
All terms and conditions apply.
High Density Urethane Laboratory Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Shipping Weight: 258 Lbs.
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module
- Sample Simulated Digital Temperature Display; .1° Resolution Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back
Web Content Viewer