Home  >  Equipment  >  Electrophoresis Systems  >  Gel Imaging and Documentation Systems  > GenoSep™ Capillary Electrophoresis Systems

GenoSep™ Capillary Electrophoresis Systems

New!
Item #: ASGENOSEP 

Simple Three-Step Workflow

From sample to results in just a few easy steps.

Step 1: Prepare Samples

Prepare samples according to the assay protocol and add the appropriate size marker and alignment marker, both supplied with the GenoSep Fragment Analysis Kit.

Step 2: Load Cartridge and Samples

Insert the ready-to-use GenoSep cartridge, load your samples, and start the run. The pre-filled, reusable cartridge eliminates labor-intensive gel preparation, reduces hands-on time, and provides consistent separation performance. Each cartridge can be reused until its maximum rated sample capacity is reached.

Step 3: Start Data Analysis

Click Run to begin the analysis. The GenoSep system separates the samples and displays electropherograms in real time as each sample is processed.

 


GenoSep Capillary Electrophoresis Systems

 

The Accuris GenoSep is a compact capillary electrophoresis system for high-resolution nucleic acid and protein characterization. The system combines automated capillary electrophoresis with sensitive fluorescence detection to deliver accurate fragment sizing, quantification, and quality assessment for DNA, RNA, proteins, NGS libraries, and cell-free DNA (cfDNA) samples.
 
 Applications

  • DNA
  • RNA
  • Protein Characterization
  • NGS Library QC
  • cfDNA Analyses

GenoSep Separation Technology

 

This instrument utilizes convenient, reusable cartridges to separate nucleic acids and proteins. Each cartridge incorporates a proprietary polymer matrix and a fused silica capillary. During analysis, programmable high voltage is applied through the capillary to generate an electric field that drives the electrophoretic migration of macromolecules through the polymer matrix. Differences in electrophoretic mobility result in size-based separation, and fluorescently labeled fragments are detected as they pass the optical detection window. User-selectable voltages enable optimization of methods for different applications and fragment size ranges.

 

Performance

 

To ensure exceptional sensitivity and reproducibility, each GenoSep cartridge is produced under a rigorous manufacturing process, helping to enable consistent results from cartridge to cartridge. Precision high-voltage control with automated instrument operation allows the GenoSep system to deliver highly reproducible migration times, enabling accurate fragment sizing and reliable comparison between runs. Consistent migration profiles provide reliable assessment of sample integrity.

The GenoSep system also provides exceptional sensitivity, with a limit of detection as low as 2 pg. This high sensitivity is achieved through LED-induced fluorescence detection, optimized optical design, and a proprietary low-background separation matrix that minimizes background noise and enhances signal-to-noise performance.

 

Software

 

The included Windows-based GenoSep software allows for instrument control and data analysis. The PC software is quick to install, set up, and begin operation.

Running an assay is simple: load the samples, select the desired method, and click Run. The software automatically controls the instrument, monitors the analysis in real time, and generates electropherograms, virtual gel images, fragment sizing info, and quantitative results.

System Specifications 

Detection TypeFluorescence
Excitation Light SourceLED
Software CompatibilityPC (Windows 10 or Above)
# of Samples/Run1-16
LOD0.2 pg/μL (optimized)
Resolution1 to 4 bp
Sample Processing Time3 to 5 Min./Sample
Sample Consumption< 0.2 uL
Fragment Size CV%≤2%
Fragment Concentration CV%≤4%
ChannelsSingle Channel
Power110-240 V/AC, 50/60 Hz
Dimensions (L x W x H)9.3 x 11.4 x 12.2 In. | 237 x 290 x 311 mm
Weight19.14 lb | 8.7 kg

 

 

Fragment Analysis Kits

 

GenoSep Fragment Analysis Kits provide a comprehensive range of cartridges for high-resolution analysis of DNA, RNA, and proteins. Specialized DNA kits support applications including PCR product analysis, genotyping, NGS library quality control, cfDNA analysis, and characterization of large DNA fragments. RNA and protein kits enable RNA integrity assessment, mRNA and low-input RNA analysis, as well as protein sizing across a broad molecular weight range. Each GenoSep cartridge delivers automated fragment analysis with accurate sizing, reliable quantification, and highly reproducible performance.

GenoSep Fragment Analysis Kits include a ready-to-use cartridge, size marker, alignment marker, separation buffer, dilution buffer, mineral oil, two buffer tanks, and two 0.2 mL PCR strip tubes. All consumables except the cartridge are available for purchase separately. Contact us for more information.   

Kit Specifications 

Item #KitSeparation RangeMax. Res.# of Sample RunsLODApplication
CE1016-DHRGenoSep High Resolution DNA Analysis Kit15-5000 bp1-4 bp2401 pg/uLSSR analysis and multiplex PCR detection
CE1016-DSRStandard Resolution DNA Analysis Kit15-5000 bp4-10 bp2401 pg/uLNGS library QC, cfDNA detection
CE1016-DHSHigh Sensitivity Resolution DNA Analysis Kit15-5000 bp4-10 bp1000.2 pg/uLLow-Concentration DNA Samples
CE1016-DLFLarge DNA Fragment Resolution Kit15-165000 bp4-10 bp24020 pg/uLLarge Genome Analysis, 3rd Generation Sequencing Libraries
CE1016-RSStandard RNA Resolution Kit20-6000 ntN/A1005ng/uLTotal RNA, mRNA, CRISPR QC
CE1016-RHSHigh Sensitivity RNA Analysis Kit20-6000 ntN/A1001 ng/uLLow-Concentration RNA Samples
CE1016-PProtein Analysis Kit5-250 kDaN/A1000.5 ng/uLProtein Sample Analysis
 
 
Item#:
ASPR1MAMYVLTTCH
 
 
SKU Number Description Type Qty Price Quantity Add to Cart
CE1016 Electrophoresis System 115 V 1/ea
24500.00
Each
CE1016-DHR High Res. DNA Analysis Kit 15 to 5000 bp 240 Runs
497.28
Each
CE1016-DSR Standard Res. DNA Analysis Kit 15 to 5000 bp 240 Runs
425.00
Each
CE1016-DHS High Sensitivity Res. DNA Analysis Kit 15 to 5000 bp 100 Runs
451.20
Each
CE1016-DLF Large DNA Fragment Res. Kit 15 to 165000 bp 240 Runs
499.00
Each
CE1016-RS Standard RNA Res. Kit 20 to 6000 nt 100 Runs
325.20
Each
CE1016-RHS High Sensitivity RNA Analysis Kit 20 to 6000 nt 100 Runs
399.00
Each
GenoSep Systems
GenoSep™ Capillary Electrophoresis Systems
Special Order
Quantity: