S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Chemicals
MIDSCI™ is Your Trusted Source for High-Quality Lab Chemicals and Reagents
Looking for reliable chemicals to power your research? MIDSCI™ delivers a full range of high-purity reagents, solvents, and buffers designed for life science, pharmaceutical, microbiology, and organic chemistry workflows. From essential acids and bases to specialized biochemicals, growth media, and DNA kits, our inventory ensures precision, consistency, and compliance, backed by Certificates of Analysis (COAs) and Safety Data Sheets (SDS).
Explore PR1MA™ Chemicals, our premium line of USP- and ACS-grade chemicals
Perfect for molecular biology, plant science, and cellular research, PR1MA™ products offer full traceability and documentation for your peace of mind.
Shop now for high-quality chemicals or contact our experts for personalized recommendations!
Looking for ways to save? Sign up for our newsletter to hear about upcoming offers!
PR1MA™ Acrylamide/bis-Acrylamide, 19:1 Ratio Solution
CAS Number: 79-06-1; 110-26-9; 7732-18-5
Storage Temp: 2-8°C
A 40% solution containing 38% (w/v) Acrylamide and 2% (w/v) bis-Acrylamide
for a monomer to crosslinker ratio of 19:1.
WARNING! This product can expose you to Acrylamide, a chemical which is
known to the State of California to cause cancer, developmental and
reproductive harm. For more information go to www.P65Warnings.ca.gov.
Research or further manufacturing use only, not for food or drug use.
- Appearance: Clear, colorless liquid
- Conductivity of Solution: ≤ 10 µmhos
- DNase/ RNase: Not Detected
- Electrophoresis: Pass Test
- pH: Report
Proudly made in the USA! Click here for more made in America products!
For any singular Distributor customer order/sale price of over $5,000 there will be no return allowed. For any order of $0-$4,999 Distributor may cancel/return any or all Products with a 15% restocking fee within 30 days after delivery of products to the customer by Distributor. After 30 days from receipt of the product from the customer, there will be no return allowed.
VitroGel® Angiogenesis Assay HC Kit
Tunable hydrogel system for 2D gel coating and 3D culture of
angiogenesis tube formation, invasion, and animal injection.
- Hydrogel Kit Only: VitroGel® AAK-HC hydrogel ( 1 mL), AAK Dilution Solution (10 mL)
- Type 1 Full Kit (Hydrogel+Supplements): VitroGel® AAK-HC (1 mL), AAK Dilution Solution (10 mL), AAK Supplement 1 (3 x 500 µL), AAK Supplement 2 (3 x 500 µL)
- Type 2 Full Kit (Hydrogel+Supplements): VitroGel® AAK-HC (1 mL), AAK Dilution Solution (10 mL), AAK Supplement 1 (6 x 500 µL)
- Type 3 Full Kit (Hydrogel+Supplements): VitroGel® AAK-HC (1 mL), AAK Dilution Solution (10 mL), AAK Supplement 2 (6 x 500 µL)
VitroGel® Angiogenesis Assay HC Kit
- Xeno-free functional hydrogel system supporting angiogenesis process
- Control and study the effect of the hydrogel mechanical properties on the angiogenesis process
- Multiple applications in one kit: Tube formation, invasion, and animal injection
- Control the hydrogel properties: Add your own growth factors and compare with positive control
- Harvest cells within 20 minutes at 37 °C without enzyme solution
VitroGel® Angiogenesis Assay Kit is a revolutionary tool for researchers to study the effect of both hydrogel properties and culture medium on angiogenesis process. The kit can be used to study the angiogenesis tube formation and invasion on both 2D hydrogel coating and 3D cell culture methods. The VitroGel® system is also good for animal injection for in vivo studies.
Angiogenesis is a highly regulated process that involves the growth of new blood vessels from the existing vasculature. This process plays an important role in both normal developmental processes and numerous pathologies, including wound healing, tumor growth, and metastasis to inflammation and ocular disease.
Traditional angiogenesis assay highly relies on natural extracellular matrix (natural ECM), which has non-adjustable hydrogel compositions and properties. Therefore, our understanding of the angiogenesis process is limited by studying the molecular cues such as growth factors and inhibitors in culture medium only. There is a lack of knowledge on how the properties of hydrogel affect the angiogenesis process.
There are two versions of VitroGel® Angiogenesis Assay Kits:
- VitroGel® Angiogenesis Assay Kit (Cat No. VHM06-K): Ready-to-use with a fixed hydrogel mechanical strength to support the angiogenesis assay with adjustable supplements.
- VitroGel® Angiogenesis Assay HC Kit (Cat No. TWG011-K): Assay kit with a tunable high concentration hydrogel to allow full control of the hydrogel’s mechanical strength with adjustable supplements.
Depending on the kit type, the tunable VitroGel Angiogenesis
Assay HC Kit can contain the following components:
- VitroGel® AAK-HC, a tunable, xeno-free high concentration hydrogel.
- AAK Dilution Solution, for adjusting the hydrogel concentration
- AAK Supplement 1, a hydrogel supplement without vascular endothelial growth factors (VEGFs) for promoting cell attachment and growth.
- AAK Supplement 2, a hydrogel supplement with VEGFs to promote tube formation and as a positive control.
- All the components can be purchased separately.
Besides molecular cues, the VitroGel® Angiogenesis Assay HC
Kit allows researchers to explore the effects of hydrogel mechanical properties
on angiogenesis. The high concentration
VitroGel® AAK-HC hydrogel is room temperature stable and can be adjusted by simply
mixing the hydrogel solution and dilution solution at different rations
(recommend 1:1 to 1:5 v/v) to achieve different mechanical strengths. The
diluted hydrogel solution can be directly mixed with supplement at 2:1 (v/v)
ratio for hydrogel formation. Researchers can adjust the molecular cues of the
hydrogel by adding the growth actors/inhibitors directly to the supplement
before mixing with VitroGel® AAK-HC.
Cells cultured in this system can be further harvested easily with the
VitroGel® Cell Recovery Solution.
|
TYPE
1 Kit Contents |
VitroGel®
AAK-HC (1 mL) |
|
AAK
Dilution Solution (10 mL) |
|
|
AAK
Supplement 1 (3 x 500 µL) |
|
|
AAK
Supplement 2 (3 x 500 µL) |
|
|
TYPE
2 Kit Contents |
VitroGel®
AAK-HC (1 mL) |
|
AAK Dilution
Solution (10 mL) |
|
|
AAK
Supplement 1 (6 x 500 µL) |
|
|
TYPE
3 Kit Contents |
VitroGel®
AAK-HC (1 mL) |
|
AAK
Dilution Solution (10 mL) |
|
|
AAK
Supplement 2 (6 x 500 µL) |
|
|
Formulation |
Tunable,
xeno-free functional hydrogel |
|
AAK Supplement
1: Without VEGFs |
|
|
AAK
Supplement 2: With VEGFs |
|
|
Use |
Angiogenesis
Assay, tube formation, invasion, animal injection |
|
Biocompatibility |
Biocompatible,
safe for animal studies |
|
Injection |
Injectable
hydrogel for in vivo studies and lab automation |
|
Cell
Harvesting |
Easy
cell recovery using VitroGel® Cell Recovery Solution |
|
pH |
Neutral |
|
Shipping |
Supplements
require dry ice shipment. |
|
Storage |
VitroGel®
AAK-HC hydrogel: store at 2-8°C |
|
AAK
Supplement 1 and AAK Supplement 2: store at -20°C |
|
|
Number
of Uses |
30-180
tests per kit |
TheWell products are never to be shipped to residential addresses. This decision has been made to safeguard the improper use and application of these products, particularly in the case of injectables and cell therapy treatments. TheWell has the right to refuse any orders that deem unfit use of their products or violate TheWell’s Terms of Use.
TheWell products are sold for Laboratory Research Use Only, Not For Diagnostic or Therapeutic use, and are not to be administered to humans.
To ensure a seamless shopping experience, please provide a non-residential shipping address during checkout where your order can be safely received and stored.
ig BL21 (DE3)
Intact Genomics chemically competent BL21(DE3) E. coli cells are suitable for transformation and routine protein expression.
Specifications
Competent cell type: Chemically competent
Derivative of: BL21(DE3)
Species: E. coli
Format: Tubes
Transformation efficiency: 1.0 x 109 cfu/µg pUC19 DNA
Blue/white screening: Yes
Shipping condition: Dry ice
Quality Control
Quality control is performed following the production of each new lot of product to ensure that it meets the quality standards and specifications designated for the product. Each lot is repeatedly compared side-by-side with leading competitors to ensure our products outperform the competitor before product launching.
Reagents Needed for One Reaction
BL21(DE3) Chemically Competent Cells: 50 µl
DNA (or pUC19 Control, 10 pg/µl): 1 µl
Recovery Medium: 1 ml
Contents & Storage
BL21(DE3) Competent Cells: -80 °C
pUC19 Control DNA: -20 °C
Recovery Medium: 4 °C
Genomic Features
BL21(DE3) chemically competent cells have the following features:
- Widely used host background
- T7 Expression Strain
- Deficient in both lon (1) and ompT proteases
- Resistant to phage T1 (fhuA2)
- B Strain
Genotype
F-ompT hsdS(rB- mB-) gal dcm (DE3)
General Guidelines
Follow these guidelines when using BL21(DE3) chemically competent E. coli.
- Handle competent cells gently as they are highly sensitive to changes in temperature or mechanical lysis caused by pipetting.
- Thaw competent cells on ice, and transform cells immediately following thawing. After adding DNA, mix by tapping the tube gently. Do not mix cells by pipetting or vortexing.
Transformation Protocol
- Remove competent cells from the -80 °C freezer and thaw completely on wet ice (10-15 minutes).
- Aliquot 1-5 µl (1 pg-100 ng) of DNA to the chilled microcentrifuge tubes on ice.
- When the cells are thawed, add 50 μl of cells to each DNA tube on ice and mix gently by tapping 4-5 times. For the pUC19 control, add 1 µl of (10 pg/µl)
- DNA to a chilled microcentrifuge tube, prior to adding 50 µl of cells. Mix well by tapping.
- Incubate the cells with DNA on ice for 30 minutes.
- After 30 minute ice incubation, heat shock the cells at 42 °C for 45 seconds.
- Transfer the tubes to ice for 2 minutes.
- Add 950 µl of Recovery Medium or any other medium of choice to each tube.
- Incubate tubes at 37 °C for 1 hour at 210 rpm.
- Spread 50 μl to 200 μl from each transformation on pre-warmed selection plates.
- Incubate the plates overnight at 37 °C.
ig 5-Alpha
Intact Genomics 5-alpha chemically competent E. coli cells are suitable for high efficiency transformation in a wide variety of applications such as cloning and sub-cloning. ig 5-alpha chemically competent cells are at least twice the transformation efficiency of the nearest competitor.
- Up to 2x higher efficiency than any competitor
- Exact same Genotype as NEB's 5-Alpha Cells
Number of Colonies per Transformation Test*
Specifications
Competent cell type: Chemically competent
Derivative of: 5-alpha
Species: E. coli
Format: Tubes
Transformation efficiency: 1 x 109 cfu/µg pUC19 DNA
Blue/white screening: Yes
Shipping condition: Dry ice
Quality Control
Quality control is performed following the production of each new lot of product to ensure that it meets the quality standards and specifications designated for the product. Each lot is repeatedly compared side-by-side with leading competitors to ensure our products outperform the competitor before product launching.
Reagents Needed for One Reaction
ig 5-alpha chemically competent cells: 50 µl
DNA (or pUC19 Control, 10 pg/µl): 1 µl
Recovery medium: 1 ml
Contents & Storage
ig 5-alpha competent cells: -80 °C
pUC19 control DNA: -20 °C
Recovery medium: 4 °C
Genotype
80 (lacZ)M15 fhuA2 (argF-lacZ)U169 phoA glnV44 gyrA96 recA1 relA1 endA1 thi-1hsdR17
General Guidelines
Follow these guidelines when using ig 5-alpha chemically competent cells.
- Handle competent cells gently as they are highly sensitive to changes in temperature or mechanical lysis caused by pipetting.
- Thaw competent cells on ice, and transform cells immediately following thawing. After adding DNA, mix by tapping the tube gently. Do not mix cells by pipetting or vortexing.
Protocol
- Remove competent cells from the -80 °C freezer and thaw completely on wet ice (10-15 minutes).
- Aliquot 1-5 µl (1 pg-100 ng) of DNA to the chilled microcentrifuge tubes on ice.
- When the cells are thawed, add 50 μl of cells to each DNA tube on ice and mix gently by tapping 4-5 times. For the pUC19 control, add 1 µl of (10 pg/µl) DNA to a chilled microcentrifuge tube, prior to adding 50 µl of cells. Mix well by tapping. 4) Incubate the cells with DNA on ice for 30 minutes.
- After 30 minute ice incubation, heat shock the cells at 42 °C for 45 seconds.
- Transfer the tubes to ice for 2 minutes.
- Add 950 µl of Recovery Medium or any other medium of choice to each tube.
- Incubate tubes at 37 °C for 1 hour at 210 rpm.
- Spread 50 μl to 200 μl from each transformation on Pre-warmed selection plates.
- Incubate the plates overnight at 37 °C.
For any singular Distributor customer order/sale price of over $5,000 there will be no return allowed. For any order of $0-$4,999 Distributor may cancel/return any or all Products with a 15% restocking fee within 30 days after delivery of products to the customer by Distributor. After 30 days from receipt of the product from the customer, there will be no return allowed.
Cyto3D™ Live-Dead Assay Kit
Live dead cell viability analysis for 3D and 2D cell
culture.
The Cyto3D™ Live-Dead Assay Kit is used to determine the live/dead nucleated cells by using a fast one-step staining procedure for analysis on a dual-fluorescence system. This kit is recommended for viability analysis of cells cultured in 3D, 2D coating and on monolayer.
- Ready-to-use
- Fast
- Sensitive
- Excellent for 3D cell cultures
- Cost-effective
Acridine orange (AO) and propidium iodide (PI), both nuclear staining (nucleic acid binding) dyes, are used in this kit. AO is permeable to both live and dead cells and stains all nucleated cells to generate green fluorescence. PI only penetrates the membranes of nucleated cells with compromised membranes and stains the dead cells to generate red fluorescence. Due to the quenching, when cells are stained with both AO and PI, all live nucleated cells fluoresce green and all dead nucleated cells fluoresce red (the PI reduces the fluorescence intensity of the AO by fluorescence resonance energy transfer (FRET)). Non-nucleated materials such as red blood cells, platelets and debris do not fluorescence and are ignored by fluorescence microscopes.
Dual-Fluorescence Viability, using AO and PI, is the
recommended viability analysis method for cell lines, primary cells, and stem
cells.
Specifications
|
Formulation |
Premixed
acridine orange (AO) and propidium iodide (PI), nuclear staining dyes |
|
Use |
Live
dead cell viability analysis for 3D and 2D cell culture |
|
Detection
Method |
Fluorescent |
|
Excitation/Emission: |
AO
(494/517nm), |
|
PI
(535/617nm) |
|
|
Standard
filters |
AO
(GFP), PI (Texas Red) |
|
For
use with (Equipment): |
Fluorescence
microscope, flow cytometer, microplate reader, fluorescence cell counter. |
|
Storage |
2 to
8°C (Protect from light) |
|
Shipping
Conditions: |
Ships
at ambient temperature |
|
Sizes |
1 mL |
|
Number
of reactions |
500
(at 2 µL per 100 µL) |
TheWell products are never to be shipped to residential addresses. This decision has been made to safeguard the improper use and application of these products, particularly in the case of injectables and cell therapy treatments. TheWell has the right to refuse any orders that deem unfit use of their products or violate TheWell’s Terms of Use.
TheWell products are sold for Laboratory Research Use Only, Not For Diagnostic or Therapeutic use, and are not to be administered to humans.
To ensure a seamless shopping experience, please provide a non-residential shipping address during checkout where your order can be safely received and stored.
For any singular Distributor customer order/sale price of over $5,000 there will be no return allowed. For any order of $0-$4,999 Distributor may cancel/return any or all Products with a 15% restocking fee within 30 days after delivery of products to the customer by Distributor. After 30 days from receipt of the product from the customer, there will be no return allowed.
VitroGel® RGD High Concentration
RGD modified – tunable, xeno-free hydrogel – high concentration (3 mL kit)
- Dilution Solution TYPE 1 contains sucrose for best osmolarity
- Dilution Solution TYPE 2 is a sucrose-free formulation for cells sensitive to the sugar level in the medium
VitroGel® RGD High Concentration is a tunable, xeno-free (animal origin-free) hydrogel system modified with cell adhesive peptide RGD to promote cell attachment and cell-matrix interactions during the 3D cell culture. VitroGel® RGD High Concentration comes with VitroGel Dilution Solution to adjust the final hydrogel strength from 10 to 4000 Pa.
VitroGel® High Concentration hydrogels are our xeno-free, tunable hydrogels for researchers wanting full control to manipulate the biophysical and biological properties of the cell culture environment. The tunability of the hydrogel gives the ability to create an optimized environment for cell growth. The hydrogel system has a neutral pH, transparent, permeable and compatible with different imaging systems. The solution transforms into a hydrogel matrix by simply mixing with the cell culture medium. No cross-linking agent is required. Cells cultured in this system can be easily harvested with our VitroGel® Cell Recovery Solution. The hydrogel can also be tuned to be injectable for in vivo studies.
From 3D cell culture, 2D cell coating to animal injection,
VitroGel makes it possible to bridge the in vitro and in vivo studies with the
same platform system.
|
Contents |
VitroGel® RGD
High Concentration, 3 mL |
|
VitroGel® Dilution
Solution, 50 mL |
|
|
Hydrogel
Formulation |
Xeno-free
tunable hydrogel modified with RGD peptide. |
|
HIGH
CONCENTRATION |
|
|
Use |
Good
for adhesion cells or cells requiring stronger cell-matrix interactions. |
|
Mix
& Match |
Can be blended with other versions of VitroGel® to create a multi-functional hydrogel |
|
Operation |
Room
temperature |
|
Hydrogel
Strength |
10 to
4,000 Pa of G’ depending on dilution ratio. |
|
Dilute with VitroGel® Dilution Solution (TYPE 1 or TYPE 2) for different concentrations. |
|
|
pH |
Neutral |
|
Color |
Transparent |
|
Cell
Harvesting |
20 min cell recovery using VitroGel® Cell Recovery Solution |
|
Injectable |
Injectable
hydrogel |
|
Storage |
Store
at 2-8°C. Ships at ambient temperature |
|
Number
of Uses |
Dilution
ratio: |
|
1:2 =
225 uses at 50 µL per well |
|
|
1:3 =
300 uses at 50 µL per well |
|
|
1:5 =
450 uses at 50 µL per well |
TheWell products are never to be shipped to residential addresses. This decision has been made to safeguard the improper use and application of these products, particularly in the case of injectables and cell therapy treatments. TheWell has the right to refuse any orders that deem unfit use of their products or violate TheWell’s Terms of Use.
TheWell products are sold for Laboratory Research Use Only, Not For Diagnostic or Therapeutic use, and are not to be administered to humans.
To ensure a seamless shopping experience, please provide a non-residential shipping address during checkout where your order can be safely received and stored.
Tris Hydrochloride
- Appearance: White, Crystalline Powder
- Purity: ≥ 99.0%
- pH (1% Aqueous): 4.2 - 5.0
- Solubility (1M Aqueous): Clear and Colorless
- Identity (FTIR): Conforms to Structure
- Loss on Drying (105°C/4h): ≤ 0.5%
- Melting Point: 149ºC - 153ºC
- A260 (40% Aqueous): ≤ 0.06
- A280 (40% Aqueous): ≤ 0.05
- Lead: 5 ppm
- RNase: None Detected
- DNase: None Detected
*Custom sizes available upon request.
DOT Information: Non-regulated.
Reporter gene based Luminescent assay systems from Perkin Elmer provide a homogeneous assay with 96, 384, and 1536 well formats, no DTT (no smell formulation), Ease of storage (2 to 8°C) and shipping (at RT). Different assay formats allow for varying levels of intensity and half-life depending on your application.
- Choose britelite plus:
- Half-life = 30 min
- Brightest signal = when looking for maximum sensitivity
- Shortest half-life = for continuous processing of samples
- Choose neolite:
- Half-life = 150 min
- High signal intensity, longer lasting signal = good balance
- For both continuous and batch processing of samples
- Best robustness (less dependent on mixing quality)
- Less sensitive to phenol red
- Can be stored 1 month at 22°C
- Choose steadylite plus:
- Half-life = 240 min
- Longest signal half-life = for batch processing of samples
- Super-sensitivity not needed
For any singular Distributor customer order/sale price of over $5,000 there will be no return allowed. For any order of $0-$4,999 Distributor may cancel/return any or all Products with a 15% restocking fee within 30 days after delivery of products to the customer by Distributor. After 30 days from receipt of the product from the customer, there will be no return allowed.
VitroGel® Angiogenesis Assay Kit
ready-to-use, hydrogel system for 2D gel coating and 3D
culture of angiogenesis tube formation, invasion, and animal injection.
- Hydrogel - Hydrogel Only: VitroGel® AAK (2 mL)
- Type 1 - Full Kit (Hydrogel+Supplements): VitroGel AAK (2 mL), AAK Supplement 1 (500 µL), AAK Supplement 2 (500 µL)
- Type 2 - Full Kit (Hydrogel+Supplements): VitroGel AAK (2 mL), AAK Supplement 1 (2 x 500 µL)
- Type 3 - Full Kit (Hydrogel+Supplements): VitroGel AAK (2 mL), AAK Supplement 2 (2 x 500 µL)
VitroGel Angiogenesis Assay Kit
- Xeno-free hydrogel system supporting angiogenesis process
- Multiple applications in one kit: Tube formation, invasion, and animal injection
- Control the hydrogel properties: Add your own growth factors and compare with positive control
- Easy, efficient, and enzyme-free cell harvesting in 20 minutes
VitroGel® Angiogenesis Assay Kit is a revolutionary tool for researchers to study the effect of both hydrogel properties and culture medium on angiogenesis process. The kit can be used to study the angiogenesis tube formation and invasion on both 2D hydrogel coating method and 3D cell culture method. The VitroGel® system is also good for animal injection for in vivo study.
Angiogenesis is a highly regulated process that involves the growth of new blood vessels from the existing vasculature. This process plays an important role in both normal developmental processes and numerous pathologies, including wound healing, tumor growth, and metastasis to inflammation and ocular disease.
Traditional angiogenesis assay highly relies on natural extracellular matrix (natural ECM), which has non-adjustable hydrogel compositions and properties. Therefore, our understanding of the angiogenesis process is limited by studying the molecular cues such as growth factors and inhibitors in culture medium only. There is a lack of knowledge on how the properties of hydrogel affect the angiogenesis process.
There are two versions of VitroGel® Angiogenesis Assay Kits:
- VitroGel® Angiogenesis Assay Kit (Ready-To-Use): Ready-to-use with a fixed hydrogel mechanical strength to support the angiogenesis assay with adjustable supplements
- VitroGel® Angiogenesis Assay HC Kit (Cat No. TWG011-K): Assay kit with a tunable high concentration hydrogel to allow full control of the hydrogel’s mechanical strength with adjustable supplements.
Depending on the kit type, the ready-to-use VitroGel®
Angiogenesis Assay Kits can contain the following components:
- VitroGel® AAK, a xeno-free ready-to-use hydrogel.
- AAK Supplement 1, a hydrogel supplement without vascular endothelial growth factors (VEGFs) for cell attachment and growth.
- AAK Supplement 2, a hydrogel supplement with VEGFs to promote tube formation and as a positive control.
The VitroGel® AAK hydrogel is room temperature stable and
can be directly mixed with each supplement at 2:1 (v/v) ratio for hydrogel
formation. Researchers can adjust the
hydrogel’s molecular cues by adding the growth factors/inhibitors directly to
the supplements before mixing with the VitroGel® AAK hydrogel. Cells cultured in this system can be
harvested further easily with the VitroGel® Cell Recovery Solution.
Contents and Specifications
|
TYPE
1 Kit Contents |
VitroGel® AAK
(2 mL) |
|
AAK
Supplement 1 (1 x 500 µL) |
|
|
AAK
Supplement 2 (1 x 500 µL) |
|
|
TYPE
2 Kit Contents |
VitroGel® AAK
(2 mL) |
|
AAK
Supplement 1 (2 x 500 µL) |
|
|
TYPE
3 Kit Contents |
VitroGel® AAK
(2 mL) |
|
AAK
Supplement 2 (2 x 500 µL) |
|
|
Formulation |
Ready-to-use,
xeno-free functional hydrogel |
|
AAK
Supplement 1: Without VEGFs |
|
|
AAK
Supplement 2: With VEGFs |
|
|
Use |
Angiogenesis
Assay, tube formation, invasion, animal injection |
|
Biocompatibility |
Biocompatible,
safe for animal studies |
|
Injection |
Injectable
hydrogel for in vivo studies and lab automation |
|
Cell
Harvesting |
Easy
cell recovery using VitroGel® Cell Recovery Solution |
|
pH |
Neutral |
|
Shipping |
Supplements
require dry ice shipment. |
|
Storage |
VitroGel® AAK
hydrogel: store at 2-8°C |
|
AAK
Supplement 1 and AAK Supplement 2: store at -20°C |
|
|
Number
of Uses |
60
uses at 50 µL per well |
TheWell products are never to be shipped to residential addresses. This decision has been made to safeguard the improper use and application of these products, particularly in the case of injectables and cell therapy treatments. TheWell has the right to refuse any orders that deem unfit use of their products or violate TheWell’s Terms of Use.
TheWell products are sold for Laboratory Research Use Only, Not For Diagnostic or Therapeutic use, and are not to be administered to humans.
Web Content Viewer