|◀ ◀ 25 - 36 of 37 ▶ ▶|
View:

Minigel System 9cm x 11cm & (1) 10 and (1) 14 tooth comb


Horizontal gel electrophoresis minigel system for 9cm x 11cm minigels. Includes gasketed UVT gel tray with fluorescent ruler, and (1) 10 and (1) 14 tooth comb, 1.5 mm thickness. Comb substitutions are available. Four year manufacturer warranty.

System description

The standard 0911 mini gel system includes a RapiCast™ gasketed gel tray for convenient gel casting right in the buffer chamber.

System features

The 0911 complete system includes these features:

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     Gasketed (cast in place) 9cm wide x 11cm long UV-transparent gel tray with built-in fluorescent ruler and 2 comb slots.
  •     One 1.5mm x 10 tooth comb
  •     One 1.5mm x 14 tooth comb
Item#:
ASMINGEL9AND11S

ENDURO Modular Vertical Gel System


A modular system allowing PAGE, electroblotting and 2D gel electrophoresis to be carried out in the same tank, simply by changing the inserts. Users can purchase only the parts they need, or a complete combined system for a cost savings over buying all three systems separately.

  • Modular Design
  • PAGE, Electroblotting and 2D Electrophoresis
  • Quick and easy set up
  • Wide range of accessories
 
MODULAR SYSTEM 
 
The modularity of the ENDURO™ System is based on three operational inserts and a common buffer tank. All three inserts, PAGE, electroblotting and 2D electrophoresis, have their own electrode assembly that connects into the lid of the buffer tank. PAGE INSERT Set up of gels is quick and easy with the PAGE insert. A set of plates are placed on either side of the insert and held into place by the pressure bar. An additional gel may be run on each side by stacking the plates. The assembly is then placed into the casting stand for pouring the gel. After the gel is polymerized, the insert is removed from the casting stand and placed in the buffer tank.
 

ELECTROBLOTTING INSERT
 
The electroblotting insert has a capacity for 3 gels. Setting up blots is easy - gels are sandwiched in the blotting cassettes with the transfer membranes. The cassettes are then placed in the insert, which is in turn placed in the buffer tank. Coiled electrodes in the insert generate a high intensity current, allowing transfer to take place in about an hour.
 

2D ELECTROPHORESIS INSERT
 
This insert is used for running the first dimension of IEF gels. Up to ten 8 cm gels are poured in disposable capillary tubes and placed in this insert. Gasketed ports allow for easy insertion and removal of tubes. Blocking plugs are included for closing off ports that are not in use.
 

BUILT FOR SAFETY AND ENDURANCE
 
For leak-proof performance and a long service life, the buffer tank is molded from high quality acrylic. Pins on the top of the inserts ensure that the lid is placed onto the insert in the proper orientation. These pins also aid in removal of the lid. Removing the lid disconnects power to the electrodes.

 
ACCEPTS MOST PRE-CAST GELS
 
Most precast gels, including NuSep™, Bio-Rad™, Invitrogen™, and Cambrex™, can be used with the ENDURO™ PAGE System. The use of precast gels saves time by eliminating the need to pour gels and wait while they polymerize.

 
WIDE RANGE OF ACCESSORIES
 
A variety of combs and spacers of varying widths are available to customize your ENDURO™ system. All are color coded and clearly marked for easy identification. Both notched and plain plates can be purchased with spacers permanently bound for easy set up. Additional fiber pads and replacement cassettes are also available as well as capillary tubes, blanking ports and tube supports. Cooling packs are also available to help reduce buffer temperature during higher voltage or longer runs.
Item#:
ASEDIROMOVERGES

Minigel System w/ 4 comb slots, 12 cm x 14 cm

Horizontal gel electrophoresis system for 12cm x 14cm minigels. Includes gasketed UVT gel tray with fluorescent ruler, and (1) 12 and (1) 20 tooth comb, 1.5 mm thickness. Comb substitutions are available. Four year manufacturer warranty.
 
System Description

This flexible system from Galileo is the perfect personal unit for a wide range of separation needs, and our most popular model.

Unit features RapidCast trays for quick in-unit gel casting of 12cm wide by 14cm long gels.

Choose a complete system or build your own custom unit from the many system components we offer.  The NEBT-80-1214 gel system is supplied with a RapidCast™ gasketed gel tray for convenient gel casting directly in the buffer chamber.  Choose from a wide variety of comb options.  All are compatible with Owl Separation Systems B2A or similar devices.  The teeth on combs marked as "microtiter" are uniformly spaced for easy loading with multichannel pipettors.System features

System Features

The Galileo 1214 complete system includes these features:

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     Gasketed (cast in place) 12cm wide x 14cm long UV-transparent gel tray with
  •     built-in fluorescent ruler and 2 comb slots.
  •     One 1.5mm x 12 tooth comb
  •     One 1.5mm x 20 tooth comb

System Options
 
The Galileo 1214 unit can be also be ordered with our new automatic buffer recirculation system (80-1214-R) or with installed buffer ports for connection to an external buffer recirculation system (80-1214-BEP)
Item#:
ASMINGEL412AND14

Horizontal Gel System, 15cmW x 25cmL


Galileo large gel systems are designed for high resolution of complex analytes. All units feature long run lengths, with medium to high capacity units available. High quality 9mm thick rugged acrylic construction, resists cracking and warping.
 
Your safety ensured with interlocking lid, protected sockets and permanently attached power cords. Epoxy sealed electrode connections, resist corrosion and leaks. Gold plated banana plugs.
Meets or exceeds IEC1010-1 standards. Safe & Reliable UV transmissible gel trays with built-in fluorescent rulers.

Large units feature trays with multiple comb slots for veratility. Machined finger grooves on the tray sides for easy and sure handling. Wide range of comb configurations, including multi-channel capability. Selected units available with buffer recirculation capabilities. Combs specifications clearly marked on each comb. Optional casting methods for flexibility, convenience and speed.

Convenient & Versatile
 

  • Exceptional resolution.
  • Platinum electrodes configured to provide uniform field for straight runs.
  • Multiple comb slot options for a wide range of sample and run-length configurations.
Item#:
ASHORIZGELSY15
Gel Size: 20cm(W) x 25cm(L)
Buffer volume: 1200ml

The IB56000 HR2025 is a high resolution system ideal for separation of nucleic acids  in agarose gels. It is also designed for rapid screening of PCR fragments, RFLP analysis or 
plasmid screening, field inversion, genomic DNA separations and electrophoresis  procedures requiring recirculation. Constructed of 3/8" cast acrylic to provide years of 
trouble-free service. Withstands high voltage and high temperatures and will not warp or crack like molded units do.

This System Comes Complete with:

  • Buffer Tank
  • Patented Vented Lid
  • IB56020 UVT Casting Tray
  • IB56030 Casting Fixture
  • Two, 2.0mm x 20-tooth combs
  • Power Cords
  • Bubble Level
  • Buffer Ports
  • 4 year warranty

 

Specifications:

Unit Dimensions: 8.3cm(H) x 26.7cm(W) x 39.4cm(L)

Gel Dimensions: 20cm x 25cm

Maximum sample capacity: 160 samples (4 combs, 40 samples each)

Buffer Capacity: 1200ml

Distance between electrodes: 35cm

Item#:
ASPCRELCTP5
Gel Size: 25cm(W) x 25cm(L)
Buffer volume: 1500ml

This high throughput system is designed to complete analysis of up to 200 samples 
from microtiter plates and is ideal for running all types of precast gels. The large format 
can run gels in less than 30 minutes.

 

Specifications:

Unit Dimensions: 8.3cm(H) x 26.7cm(W) x 39.4cm(L)

Gel Dimensions: 25cm x 25cm

Maximum sample capacity: 300 samples (6 combs, 50 samples each)

Buffer Capacity: 1500ml

Distance between electrodes: 35cm

This System Comes Complete with:

  • Buffer Tank
  • Patented Vented Lid
  • IB57020 UVT Casting Tray
  • IB57030 Casting Fixture
  • Four, 2.0mm x 50-tooth combs
  • Power Cords
  • Bubble Level
  • Buffer Ports
  • 4 year warranty
Item#:
ASPCRELCTP4

Gel Size: 10cm(W) x 15cm(L)
Buffer volume: 500ml

The MP-1015 is the ideal Multi-Purpose gel box for both extended high resolution, linear runs, and economical quick screens. The MP-1015 contains buffer recirculation ports for long runs requiring recirculation. The MP-1015 is constructed of 3/8" thick, cast acrylic, to withstand high voltages and temperature extremes. Unlike single piece molded units, the MP1015 will NOT warp or crack during extended use. This unit is designed to provide years of continuous operation.

Specifications:

Construction: Buffer tank is constructed of 3/8" thick, cast acrylic. Casting tray bottom is constructed of UV transmittance cast acrylic to allow viewing of the gel with a UV light source

Unit Dimensions: 7cm(H) x 16.5cm(W) x 30.5cm(L) Gel Dimensions: 10cm x 15cm

Shipping weight: 4.5 Lbs.

Distance between the electrodes: 27cm

Maximum Sample Capacity: 80 samples (4 combs, 20 samples each)

Buffer Capacity: 500ml

The maximum suggested applied voltage for the electrophoresis of DNA in agarose gels using the IB53000-MP1015 is 140 volts. In a 1% TBE gel, this translates into a run time of approx. 1 hour. Lower voltages can be used of course, and as a general rule a 70 volt run will take twice as long as a 140 volt run. Higher voltages can be used to decrease run time however, higher voltages can produce excessive heat and decrease sample resolution.

Complete System Includes:

  • Buffer Tank

  • Patented Vented Lid

  • IB53020 UVT Casting Tray

  • IB53030 Casting Fixture

  • Two, 2.0mm x 16-tooth combs

  • Power Cords

  • Bubble Level

  • Buffer ports

  • 4 year Warranty
Item#:
ASPCRELCTP3

Gel Size: 7cm(W) x 10cm(L)
Buffer volume: 250ml

Designed for Quick Screening and rapid, linear separation of nucleic acids. The QS710 requires 
minimal set-up and provides excellent band resolution and consistent lane-to-lane mobility 
for accurate results. A versatile system great for applications requiring quick screens such as 
fragment analysis and recombinant screening.

 

Specifications:

Construction: Buffer tank is constructed of 3/8" cast acrylic.

Casting Tray bottom is constructed of UV Transmittance cast acrylic to
allow viewing of gel with a UV light source

Unit Dimensions: 6.4cm(H) x 11.4cm(W) x 22.2cm(L)

Gel Dimensions: 7cm x 10cm

Distance between the electrodes = 19.3cm

Maximum sample capacity = 30 samples (2 combs / 15 samples ea)

Buffer Capacity = 250ml

Shipping weight = 3.0 lbs.

The maximum suggested applied voltage for the electrophoresis of DNA in agarose gels using the QS710 is 100 volts. In a 1% TBE gel, this translates into a run time of approx. 1 hour. Lower voltages may be used, of course, and as a general rule, a 50 volt setting will take twice as long as a 100 volt setting.

The suggested run parameters for the electrophoresis of RNA in agarose gels containing formaldehyde are 60 - 80 volts.

Complete System Includes:

  • Buffer Tank
  • Patented Vented Lid
  • IB51020 UVT Casting Tray
  • IB51025 Casting Fixture
  • Two, 1.5mm x 8-tooth combs
  • Power Cords
  • Bubble Level
  • 4 year warranty
Item#:
ASPCRELCTP2

The IBI "Lab-Pal" has been designed with the teaching lab in mind. The IB50000 utilizes  two glass slides, measuring 2" x 3", for casting the agarose. The small glass slide 
format is ideal for minimizing agarose use while still being an excellent teaching tool for students just learning about the separation of DNA molecules. 

Agarose slides can be cast days in advance and stored in buffer for later use. This helps maximize  class time

System Includes:

  • Vented lid
  • Dual casting fixture
  • 4 glass casting slides
  • (2) 1.5mm x 5-tooth combs
  • Bubble level
  • Power cords
  • 4 year warranty
Item#:
ASPCRELCTP1

Minigel System 7cm x 8 cm & (1) 6 and (1) 10 tooth comb


Perfectly sized for rapid analysis of small analytes like PCR and RE fragments. This unit features a RapidCast gasketed tray for quick in-unit gel casting.

System Description

Horizontal gel electrophoresis minigel system for 7cm x 8cm minigels. Includes gasketed UVT gel tray with fluorescent ruler, and (1) 6 and (1) 10 tooth comb, 1.5 mm thickness. Comb substitutions are available. Four year manufacturer warranty.

The standard 0708 mini gel system includes a RapidCast™ gasketed gel tray for convenient gel casting right in the buffer chamber.

System features

The 0708 complete system includes these features:

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     Gasketed (cast in place) 7cm wide x 8cm long UV-transparent gel tray with built-in fluorescent ruler and 2 comb slots.
  •     One 1.5mm x 6 tooth comb
  •     One 1.5mm x 10 tooth comb
Item#:
ASMINGEL7AND8S

Horizontal Electrophoresis System, 20 cm x 25 cm

Horizontal Large Gel Electrophoresis System for 20cmW x 25cm gel. Includes 20cm x 25cm UVT Gel Tray w/ end gates & (1) 16, (1) 24 and (1) 36 Tooth, 1.5 mm thickness. Includes four year warranty.

 The 81-2025 is a medium capacity system. With a maximum run length of 25cm, the unit can provide high resolution of complex analytes. Or, fitted with maximum capacity combs in all of the tray's 6 comb slots, the unit can handle up to 168 samples. The 2025 features the Galileo ExpressCast gel casting system for quick, tape-free gel casting and includes a built-in bubble level and leveling screws for convenient level adjustment. You may choose from a wide variety of comb options to customize your order.

  •     Heavy duty lower buffer chamber
  •     Interlock safety lid with attached leads
  •     End gated 20cm wide x 25cm long ExpressCast™ UV-transparent gel tray with built-in fluorescent ruler and 6 comb slots.
  •     One 1.5mm x 16 tooth combs, one 1.5mm x 24 tooth combs, one 1.5mm x 36 tooth combs
Galileo automatic buffer recirculation reduces detrimental ion and pH gradients in your buffer, encourages even migration of nucleic acids, and is ideal for long running gels. Buffer recirculation can also prevent glyoxalated RNA from dissociating in the presence of ion gradients.

The system is simple and self contained. A trapping system captures hydrogen bubbles created by electrolysis of the buffer at the cathode (-) end of the unit. As these bubbels move up the canted recirculation tube, they carry buffer along with them and provide a gentle and reliable recirculation system. This system is self regulating and no additional tubing or pumps are required.
Item#:
ASHORIZELCTSY20


LabValues 2026 Promo!

For a limited time, enjoy 30% OFF the Enduro™ Gel XL System (E0160)!

WAS $821.41 | NOW $574.99

Click here for more LabValues or see flyer for more details.

Offer cannot be combined with other discounts or institutional pricing.
Offer not valid on previous purchases. Promo valid from 7/27/26 to 12/31/26 or while supplies last.
 
All terms and conditions apply.

 
  • POWER- 150v/400ma
  • CONTROL- set voltage, amperage and time
  • FLEXIBILITY - runs 6x6cm to 12.5x12cm gels
  • THROUGHPUT - up to 112 samples at once
  • CONVENIENCE - casting set and combs included
  • WARRANTY: 1 year

Labnet's Enduro Gel XL includes all components necessary to cast and run horizontal gels: gel trays, combs, casting stand, gel tank and digital power supply. The migration tank, gel trays and multichannel combs are molded for leakproof performance and a long service life. The direct connection of the power supply into the gel box eliminates the need for power leads.

Pressing the eject button separates the gel box and power supply. Reconnecting is easy-just press the two pieces together. The power supply can be set to either constant voltage or constant current with automatic crossover between the two parameters. Parameters are shown on the large digital display that is easily visible from a distance.

There are three different gel options for the Enduro Gel XL; 12.5 x 12cm, 12.5 x 6cm and 6 x 6cm. One larger gel with multiple combs will accommodate up to 112 samples. Or run two small gels or four micro gels at the same time. Cassettes protect fragile electrodes from damage and allow for easy replacement.

A magnetic sensor allows current to flow to the electrodes only when the lid is in place. If the lid is removed while the system is operating, current is immediately shut down. In addition, the lid of the gel box is vented to dissipate heat produced during electrophoresis. To aid in visualizing the gel while it is running, there is a clear window over the gel platform.

Product Specifications 

Overall dimensions (WxLxH) 24.5 x 17.0 x 6.2 cm
Gel tank dimensions (WxLxH) 18.3 x 16.4 x 5.6 cm
Power supply dim. (WxLxH) 7.5 x 17.0 x 6.2 cm
Maximum sample capacity 112 (4-28 tooth combs)
Gel capacity Per run
Large (12.5 x 12 cm) 1 each
Small (12.5 x 6 cm) 2 each
Micro (6 x 6 cm) 4 each
Buffer capacity 300mL
Input voltage AC 100-240V, 50/60 Hz
Output voltage 10 - 150 V
Output current 10 - 400 mA
Timer up to 99 hours or continuous
Memory Last programmed parameters saved
Item#:
ASPCRELCTP21
|◀ ◀ 25 - 36 of 37 ▶ ▶|
View: