Cryogenic Equipment

Reliable Equipment for Ultra-Low Temperature Storage

Protecting sensitive biological materials requires precision and performance. At MIDSCI, we offer high-quality cryogenic freezers, liquid nitrogen storage systems, and essential accessories designed for secure, long-term sample preservation.

From cell lines and plasma to reagents and critical research samples, our cryogenic solutions deliver temperature stability, energy efficiency, and safety, so your lab can operate with confidence. Explore our full range of cryogenic tanks, dewars, valves, and transfer components to keep your workflow running smoothly.

Not Sure What Cryogenic Setup You Need?

Whether you're upgrading your cryogenic storage or setting up a brand new cryo workflow, our Lab Consultants are here to help. We’ll walk you through tank size, liquid nitrogen usage, cryogenic valve configurations, and everything in between.

Contact us today to protect your samples with the reliability and support only MIDSCI delivers, and sign up for our newsletter to be among the first to hear about limited‑time offers and special savings opportunities.

|◀ 25 - 29 of 29 ▶|
View:

Haier Liquid Nitrogen Tank Temperature Detector

  • The temperature monitor provides continuous and reliable monitoring of the temperature in the container. It is the ideal choice for long-term monitoring of sample storage temperature and reminding users to add liquid nitrogen.
  • The temperature monitor ZTC-100A has real-time temperature display function, and can also provide the following alarms: 
    • Over temperature alarm
    • Sensor error acousto-optic alarm
Item#:
ASLN2TANKTEMPD

Haier Liquid Nitrogen Tank Smart Cap

  • Independent, high accuracy measuring system for liquid level and temperature
  • Real time display of level and temperature, alarm setting via phone message, email, and wechat
  • Wireless transmission of level and temperature data to a data interrupter
  • Fluid level and temperature data uploaded remotely to cloud terminals for recording, printing, and storage
  • Built-in high efficiency lithium battery for longevity

SmartCap is a low energy consumption IoT-based module that can monitor liquid nitrogen level and temperature in a liquid nitrogen tank. It is suitable for aluminium alloy liquid nitrogen tanks with opening port size of 50 mm, 80 mm, 125 mm, 216 mm. The built-in high efficiency lithium battery can operate the device for more than two years. 

Item#:
ASLN2TANKSMARTCAP
Discontinued, Contact us for more options!


These models are being discontinued.

Please visit our Haier LN2 Smart Type Biobank Series for Large Scale Storage

page for the new and improved models!

Have questions or need more information? Feel free to contact us! 


Haier Liquid Nitrogen Biobank Series for Large Scale Storage Smart Type

  • LN2 Splash proof
  • Data Logging
  • Hot Gas Bypass
  • From 13,000 to 94,875 Cryovials
  • Self-diagnostics
  • Vapor Phase Storage
  • Lockable Lid
  • Liquid Phase Storage
  • One-touch Defogging
  • 5 Year Vacuum Warranty
Biobank series for large scale storage is designed to ensure the maximum storage capacity with the minimum consumption of liquid nitrogen to lower the overall cost of operation.

Product Advantages
  • Optimal Use of Storage Space 
    • Racks are stored on the rotating tray with an appropriate distance from the wall of the chamber. Liquid nitrogen or supercooled nitrogen vapor is filled in the space between the tray and the wall to maintain temperature uniformity. Storage space is equally divided into four or six fan-shaped storage areas which are clearly labelled. Each storage room is easily rotated to the opening of the tank for convenient sample access.  
  • Designed for Both Liquid and Vapor Phase Storages
    • Each model from the Biobank series for large scale storage is designed for both liquid and vapor phase storage. For the vapor phase storage operation process, samples are located away from the liquid nitrogen at a uniform temperature close to that of liquid nitrogen.
  • Advanced Vacuum Technology and Superinsulation Technology
    • Haier Biomedical’s Liquid Nitrogen Storage System Biobank series for large scale storage applies advanced vacuum technology and superinsulation technology to ensure storage safety and temperature uniformity while reducing the consumption of liquid nitrogen. The temperature difference of the entire storage area does not exceed 10°C, even during the vapor phase storage process, the temperature near the top of the shelf is as low as -190°C.

Item#:
ASHAIERLN2LARGE

Liquid Nitrogen Tank Self-Pressurized Series

Liquid Nitrogen Supplement Series for LN2 Storage and Supply incorporates the latest innovation, its unique design utilises the pressure generated from the vapourisation of a small amount liquid nitrogen to discharge LN2 into other containers. Storage capacities range from 5 to 500 litres.
 

Features:
  • All Models are Equipped with Safety Valve. Models 200L and Above Have Additional Rupture Disc
  • Rotary Ring Construction
  • Labelled Valves for Easy Identification
  • All Welded Stainless Steel Construction
  • 5 year Vacuum Warranty
 

Specifications:

 
 ModelVolume of LN2(L)LN2 Output (L/Min)Static
Evapouration
Rate* (%/d)
YDZ-55L20.15
 YDZ-1515L20.38
 YDZ-3030L30.75
 YDZ-5050L31
 YDZ-100(K)100L41.3
 YDZ-150150L61.95
 YDZ-200(K)200L82.4
 YDZ-240K240L82.9
 YDZ-300(K)300L83.3
 YDZ-500(K)500L105.5
Item#:
ASLIQNITSELFPRES

Haier ULT Freezer Back Up System 

  • Connect your Haier Biomedical or other ULT freezer to a liquid CO2 tank as backup security. 
  • When storing clinical samples and other "one of a kind" samples, a CO2 backup system provides an additional level of protection to keep samples frozen in the unexpected event of a power outage or other electronic system failure. 
  • Works with any ULT with an internal port.
  • Small footprint and simple to program and operate. 
  • The unit features a liquid CO2 test button to ensure the backup system is working and a low CO2 alarm system that alerts the user when liquid CO2 canister is low. 
  • The unit is covered in stainless steel and the input pipe id designed for flexibility and ease of cylinder positioning. 
  • A durable battery lasts up to 48 hours. 

Item#:
ASFREZBAUPSY
|◀ 25 - 29 of 29 ▶|
View: