S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Instruments
High-Quality Laboratory Instruments for Reliable Research
At MIDSCI™, we offer products designed to meet your lab’s evolving needs. This includes a robust selection of laboratory instruments to support research across the life sciences.
MIDSCI™ offers a comprehensive selection of laboratory instruments designed to keep your research accurate, efficient, and compliant. From pH meters, microscopes, and spectrophotometers to balances, refractometers, and thermal cyclers, our products support workflows in cell culture, microbiology, chromatography, and pharmaceutical development. Every instrument is backed by quality assurance and expert support to help your lab run smoothly.
Need More Than Instruments? Shop now and explore our full catalog of chemicals, lab supplies, and equipment, or contact us today for personalized recommendations, assistance, and more.
We run promotions often, so check back regularly or sign up for our newsletter to stay ahead of the next great deal.
SmartReader™ MultiMode Plate Reader
- Intuitive, 10-inch color touch screen
- Stand-alone system with optional PC software (FDA CFR Part 11)
- Monochromator-based system for UV through visible absorbance
- Filter module system for fluorescence assays
- Advanced PMT detector for luminescence assays
- Optional automatic injection modules for flash luminescence
- ELISA Assays
- Colorimetrics Assays (Bradford, Lowry, etc.)
- Enzyme Kinetics
- Spectral Scanning
- DNA & RNA Analysis
- …and more
STAT FAX 4200 Microplate Reader
The Stat Fax 4200 Microplate Reader is a compact, microprocessor-controlled, multi-purpose
photometer system designed to read and calculate the results of assays, which are read in 96
well microtiter plates or strip trays. The microplate reader may be used for in-vitro diagnostics. It is a user-programmable open system with selectable plate formatting, alphanumeric test naming, automatic interpretation options, duplicate well options, curve plotting and editing, flags and error messages from which the user can create a menu of pre-programmed assays for instant recall. This instrument is intended to be used as a stand-alone instrument without a PC but it has a connection in the event a user wishes to download results.
Stat Fax 4200 reads monochromatically (optional) or bichromatically (optional) and has two
models:
- Four-filter model (405, 450, 492, and 630 nm)
- Six-filter VIS model (405, 450, 492, 545, 600, and 630 nm)
Substitute filters in the range of 405 nm – 750 nm are available on special order
models.
Stat Fax 4200 accepts all standard microplates. Trays containing microstrips may also be read
whether they are 12 wells in length, 8 wells or even partial strips.
The software allows the operator to create, edit and store assays. Standard
curves are also stored in this memory. Test protocols remain stored until either changed or
deleted by the user.
TheStat Fax 4200’s optical system provides an economical and low maintenance design which reads 8 wells simultaneously. A 96 well plate can be read and printed in the absorbance mode in approximately ten seconds. Light from a lamp installed in a sealed light-tight compartment is filtered using a rotating filter wheel. The filtered light is then divided into 8 channels using a fiber optic bundle. The plate carrier precisely positions each row of 8 wells into the optical path for reading. Light passing through the 8 wells is directed to 8 photo-detectors. The filter wheel moves to a second position to read the 8 wells at a second wavelength. Using bichromatic differential absorbance values corrects for optical imperfections in the plastic wells and removes the effects of meniscus and turbidity.
Specifications: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 4.0 Absorbance Units (A) |
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
Stability: |
Drift of no more than 0.005A in 8 hours |
Light Source: |
Halogen lamp with lamp saver feature |
Standard Wavelengths: |
405, 450, 492, and 630nm. 6-filter: 405, |
450, 492, 545, 600, and 630nm. Filter |
|
options from 405nm to 700nm |
|
Filter Type: |
IAD hardcoat interference, 10nm half bandpass |
Vessel: |
Standard 96-well microplates, or strip trays |
Electronic |
|
Display: |
Interactive touch screen 5.7” (14.5cm) |
LCD, color graphic display |
|
Printer: |
Thermal 64 characters per line, plus graphics |
Power Requirements: |
100-240V AC, 1.2A, 50-60Hz (universal |
input, auto sensing) |
|
Interface: |
USB mouse; USB port used for thumb |
drive interface for firmware updates |
|
(mouse not included; thumb drive not |
|
Speed: |
Reads absorbance of 96 wells in about |
10 seconds |
|
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Cubic Spline, Cut Off Mode |
|
Test Storage: |
Stores 120 tests; stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges, |
|
standard values, test names, and |
|
previous standard curve |
|
Dimensions: |
Approximately 13.5”Wx17”Dx8-1/4”H |
(34.3cmx43.2cmx21cm) weight 12 lbs |
|
(5.5kg) | |
STAT FAX 3300 Biochemistry Analyzer
Stat Fax® 3300 is designed for the processing of biochemistries, tube method immune assays, and drug assays from human serum, plasma, or urine. A removable flowcell installs in the read well to provide extremely rapid fluid sampling with low carryover. A builtin vacuum pump and an external waste bottle with level sensing are supplied standard. When the Flowcell is removed, the instrument accepts standard 12 mm round tubes as well as 1 cm square cuvettes. The design of the instrument includes many features to minimize operator error, such as stable factory calibration, automatic zeroing, complete operator prompting, detailed labeling, pre-programmed calculations, visual and audible
feedback, flags and error messages, minimal maintenance requirements. Test parameters, and standard curves are stored in memory for later recall. The Stat Fax® 3300 will store up to 120 tests in memory to be recalled for later use and allows for creation of Levey-Jennings plots for QC. In addition, it will store 512 Patient Results, 512 Control Results, 20 Patients on Worklist, and 15 tests per patient.
SPECIFICATIONS: |
|
Photometric |
|
Linear Measurement Range: |
0.0 to 3.5 (flow-cell mode) |
|
|
Photometric Accuracy: |
+/- (1% +/- 0.010) 0.0 through 1.5 ABS |
+/- (2% +/- 0.010) 1.5 through 3.0 ABS |
|
|
|
Stability: |
Drift of no more than 0.005A in 8 |
hours/bichromatic |
|
|
|
Light Source: |
Tungsten Halogen, 10 Watt, with |
automatic lamp saver |
|
|
|
Standard Wavelengths: |
340, 405, 505, 545, 580, and 630nm |
alternate filters available from 330 to |
|
750nm; an eight position filter wheel is optional |
|
|
|
Filter Type: |
IAD hardcoat interference, 10nm half |
Bandpass |
|
|
|
Tube Size: |
12mm round is standard |
|
|
Minimum Sample Volume: |
1mL for 12mm round tube |
250uL for flowcell |
|
|
|
Display: |
240x128 Graphic LCD w/ Backlight |
|
|
Printer: |
Thermal dot matrix with graphic capability |
Power Requirements: |
Auto-Switching Power Supply |
|
|
Voltage source: |
90 – 264 VAC |
|
|
Certifications: |
CE |
|
|
Speed: |
Reads, calculates and prints results, 3 |
seconds per tube |
|
|
|
Calculation Modes: |
Factor, Single Standard, Point-to-Point, |
Regression, Index Mode |
|
|
|
Test Storage: |
Stores 120 tests. Stores all parameters |
including wavelengths, calculations, unit |
|
codes, linear and normal ranges rate |
|
timing, standard values, test names, and |
|
previous standard curve. |
|
|
|
Dimensions: |
40cm (L) x 37 cm (W) x 14 cm (H) lid |
closed (30 cm lid opened), 14 lbs (6.4 kg) |
|
Lumate Microplate Luminometer
LuMate is a compact microplate glow luminometer. Its streamlined design with minimal footprint offers superb optics to fit any size lab bench. LuMate teams up with your PC to provide full access to high level software for curve fitting, reporting, and data storage to meet the requirements of modern laboratories. Instrument and software come ready to "plug and play" with your PC.
Easy & Automatic
Simply select an assay from the stored menu and load the plate. LuMate automatically reads the plate, precisely measuring and reporting the light output from each well. LuMate runs hormones and many other applications, with on-board calculations for point to point, linear and log regressions, and log logit modes. A built in reference assures continuous calibration.
Specifications
| Optical | |
| Detection Mode | Glow Luminescence |
| Sensitivity/Detection Limit | HRP 1 X 10-18 moles, ALP 1 X 10-21 moles |
| Linear Dynamic Range | 106 RLU |
| Cross talk | Less than 2.5 X 10-4 |
| Detector | Photomultiplier (PMT) |
| Spectral Response Range | 300-650 nm |
| Peak Wavelength | 400 nm |
| Vessel | 96 wells in strip tray or plate |
| Electronic | |
| PC connection | USB port |
| Microprocessor | eZ80 |
| Plate Transport | Stepper motor |
| Power Requirements | 100V-250 AC, 50-60 Hz (auto-sensing) |
| Software | |
| PC Interface | LuMate Manager Software |
| Calculation Modes | Multipoint calibration with Regression or Point to Point curve fit with Curve storage option; Relative Light units |
| Additional Features | User-programmable open system with curve plotting and editing Selectable plate formatting with duplicates and end-reading selections Multiple timed reading options Automatic interpretation options Alphanumeric test naming Flags and error messages |
| Other | |
| Certifications | NRTL listed, CE marked |
| Enclosure | All metal enclosure |
| Dimensions | 7.5 X 8 X 16 inches (19 X 20.3 X 42 cm); 11 lbs (5 kg) |
Item 685-SC
This double beam, scanning, UV/Visible spectrophotometer has a variety of programmed measurement modes for photometrics, concentration, multi-wavelength, spectrum scanning, kinetics, quantitation, DNA and protein analysis making it ideal for a number of applications.
The stable optics and two detectors measure your samples and reference simultaneously providing superior measurement accuracy.
The variable spectral bandwidth provides your experiments with robust detection and quantitation limits, as well as optimal data precision and repeatability. This flexible platform allows the user to comply with multiple regulatory agencies using one spectrophotometer- saving money and time. Three scan speeds are available with wavelength scan intervals of 0.1, 0.2, 1, 2 or 5 nm. The large sample chamber is outfitted with a 10 x 10 mm cuvette holder, but allows for an 8-position cuvette changer (order 83070-61 separately) for flexibility.
The integrated user interface provides local controls with the touch of a keypad. The colored graphical display is easy to read and will display spectrum as well as kinetic curves. Prism PC software is supplied with the spectrophotometer to assist the user with post-measurement analysis. The Prism PC software can be used to fully control the spectrophotometer and comes pre-loaded with methods for DNA analysis, including 260/280 and 260/230 ratios with 320 nm correction. Under the multi-wavelength measurement mode, up to 20 wavelengths can be measured simultaneously and quantitation curves can be created by measuring up to 200 standards.
Operating system compatibility: Windows 2000, XP, Vista, Windows 7
Specifications & Description
- Stray Light<0.05%T at 220 nm, 360 nm
- Beam TypeDouble
- Bandwidth0.5 nm, 1.0 nm, 2.0 nm, 4.0 nm, 5.0 nm (variable)
- Min Wavelength (nm)190
- Max Wavelength (nm)1100
- Wavelength Noise<0.0005 A
- Wavelength Accuracy±0.3 nm at 0.5 and 1 nm bandwidth; ±0.5 nm at 2, 4 and 5 nm bandwidth
- Wavelength Reproducibility±0.2 nm
- Min Photometric - Transmittance (%T)1
- Max Photometric - Transmittance (%T)200
- Min Photometric - Absorbance (A)-0.3
- Max Photometric - Absorbance (A)3
- Photometric Accuracy±0.002 A (0-0.5 A); ±0.3%T (0-100%T)
Item 632-521
This easy-to-use spectrophotometer is ideal for the busy technician or student. Wavelength calibration is automatic at start-up and includes an auto-zero (% transmittance) functiona significant time saver. This spectrophotometer is fully GLP (Good Laboratory Practice) compliant. Each sample reading is given a time and date stamp and easily connects to a printerthen simply push the print key to send data.
The included 63-Zero PC software allows you to take and control measurements remotely, and export data and results to Excel, Word, Power Point, and other software applications for storage, reporting, or presentation. Transmittance, absorbance, or concentration with factor value, as well as wavelength are simultaneously. The digital, dual-line LCD shows error messages, prompts, mode indication, and concentration units (ppm, mg/L, g/L, M, %, or blank).
Specifications & Description
The four new spectrophotometers in the Jenway 73 series range include models 7300 and 7310 which cover the visible region of the spectrum. The 7305 and 7315 models use a flash xenon lamp to extend the wavelength range into the UV region of the spectrum.
The basic models, 7300 and 7305, feature measurement modes for absorbance, % transmittance, and concentration. The advanced models, 7310 and 7315, introduce additional measurement modes such as scanning, kinetics, and quantitation.
- 5nm spectral bandwidth
- Absorbance range -0.3 to 2.5 Abs
- Icon driven software
- Results and method saving to USB memory stick (7310 and 7315 only)
- Autologging capabilities
- Free bi-directional PC software
- 3 year warranty including xenon lamp
730-001 |
730-501 |
731-001 |
731-501 |
|
| Weight (lbs) | 13.2 |
|||
| Dimensions (WxLxH) (in) | 10.8 x 15.7 x 8.8 |
|||
| Warranty | 3-yr, including xenon lamp |
|||
| Wavelength | ||||
| Range: | 320-1000nm |
198-1000nm |
320-1000nm |
198-1000nm |
| Light Source: | Tungsten halogen |
Xenon |
Tungsten halogen |
Xenon |
| Resolution: | 1nm |
|||
| Accuracy: | ±2nm |
|||
| Repeatability: | ±0.5nm |
|||
| Spectral bandwidth: | 5nm |
|||
| Photometrics | ||||
| Transmittance: | 0-199.9% |
|||
| Absorbance: | -0.300 to 2.500A |
|||
| Accuracy: | ±0.01Abs at 1.000 Absorbance |
|||
| Resolution: | 0.1%T, 0.001A |
|||
| Concentration | ||||
| Range: | -300 to 9999 |
|||
| Resolution: | Selectable 1/0.1/0.01/0.001 |
|||
| Calibration: | Blank with single standard or factor |
|||
| Factor: | 0.001 to 10000 |
|||
| Standard: | 0.001 to 1000 |
|||
| Quantitation: | ||||
| Range: | n/a |
n/a |
-300 to 9999 |
|
| Resolution: | n/a |
n/a |
Selectable 1/0.1/0.01/0.001 |
|
| Calibration: | n/a |
n/a |
Blank with up to 6 standards |
|
| Curve fit stats: | n/a |
n/a |
Quadratic, quadratic through zero, linear, linear through zero, interpolate |
|
| Kinetics | ||||
| Measurement time: | n/a |
n/a |
2 to 9999 seconds |
|
| Calibration: | n/a |
n/a |
Blank with a single standard or factor |
|
| Resolution: | n/a |
n/a |
Selectable 1/0.1/0.01/0.001 |
|
| Display: | n/a |
n/a |
Graphical and concentration |
|
| Analysis: | n/a |
n/a |
Concentration, rate of change, initial and final absorbance, or % transmittance |
|
| Spectrum: | ||||
| Scan interval: | n/a |
n/a |
Selectable 1, 2, or 5nm |
|
| Analysis: | n/a |
n/a |
Absorbance, or % transmittance and peak and valleys |
|
| Analysis: | n/a |
n/a |
Concentration, rate of change, initial and final absorbance, or % transmittance |
|
- Highly accurate results - guaranteed via monolithic weigh cell technology invented by Sartorius
- Fastest stabilization time in its class - using state-of-the-art weighing sensors
- High chemical resistance - ensured using parts made from hard-wearing polybutylene terephthalate (PBT), stainless steel and glass
a budget price, this is the only balance in its class featuring isoCAL, LED touch technology and 12 built-in
applications. Backed by almost 150 years of German engineering expertise, and available in 40 different
models, you'll easily find an Entris® II balance that exactly meets your specific weighing needs.
Display
Intuitive, wear resistant LED screen with touch technology
Built-in Applications
- Weighing | Dosing
- Counting
- Percentage weighing
- Mixing | Net total
- Components | Totalizing
- Animal weighing
- Calculation | Free factor
- Density determination
- Underfloor weighing feature for bigger samples
- Statistics
- Peak hold
- Check weighing
- Mass unit conversion
English, German, France, Italian, Spanish, Portuguese, Russian, Polish
Protection
- Chemical resistant housing parts
- Glass parts of the draft shield are coated to reduce electrostatic influences
- Display foil (available as accessory)
- Dust cover for balances with draft shield
, Scale
- Pressure-sensitive counting
- Average count facility
- Bright white energy saving LED lighting
- With BioCote antimicrobial protection
- Audible confirmation
- Choice of light or dark background
- Connectivity to printer or computer
Touch pressure with felt tip marker on petri dish registers cumulative count on the digital display with confirmation by audible tone (can be turned on or off). The pressure required to register a count can be adjusted to suit each user. Averaging facility calculates average count over multiple plates. Counting results as well as useful statistics including SD can be sent directly to the accessory printer or to a computer via a USB cable supplied.
Sub-stage illumination by low energy bright LED's allows glare-free optimum viewing. A switchable black background is provided to enhance viewing of translucent and difficult to see colonies. Supplied with a Wolffhuegel graticule, segmentation dish and dish centering adapters to facilitate use with 50mm to 90mm dishes. A choice of magnifiers and a printer are available as optional accessories.
Technical Specifications
| Lighting | White LED array |
| Digital display | 3 digit LED |
| Count | 0 to 999 |
| Dimensions (w x d x h), in. | 12 x 12 x 5.5" |
| Mass, lbs | 3.3 |
| Electrical supply | 120 to 230V, 50 / 60Hz, 70W |
3520 Bench pH/mV Meter (US)
- Ideal for quality control and GLP applications
- Up to 3 decimal place resolution
- 1, 2 or 3 point pH calibration
- Automatic or manual buffer selection
- Multiple language options
- Storage of up to 500 results
- RS232 connection to printer or PC or infra-red (IrDA) communication
- GLP compliant
The 3520 dynamic pH/mV meter offers research grade specifications with a comprehensive range of features and functions, making it suitable for the broadest range of research, general laboratory, QC and GLP based applications. The built in data logger can store, print or output readings based on a wide range of trigger options, making this model suitable for monitoring and controlling pH levels.The 3520 pH/mV meter is supplied with glass combination pH electrode (924 005), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH 4, 7 and 10 buffer sachets and US power supply.
Parameter
3520
pH range
-2.000 to +20.000
pH resolution
0.001/0.01/0.1
pH accuracy
±0.003
Calibration
User selectable 1, 2 or 3 point
Automatic buffer recognition
Jenway (2.00, 4.00, 7.00, 9.20 and 10.00), DIN, NIST, JIS
mV range
±1999.9mV
mV resolution
0.1/1mV
mV accuracy
±0.2mV
Temperature range
-10 to 105°C
Temperature resolution
0.1°C
Temperature accuracy
±°0.5°C
ATC range
0 to 100°C
Alarm points
-2.000 to 19.999pH
GLP
Calibration reminder interval (1 to 999hrs)
Alarm outputs (open collector and audible).
Security code protected dataOutputs
Analogue, RS232and IrDA
Connector
BNC
Power
9V AC ±10% @ 50/60Hz
Size (l x w x d)
210 x 250 x 55mm
Weight
850g
3540 Bench pH/conductivity Meter (US)
- Simultaneous display of pH and conductivity
- 2 independent channels to prevent interference between probes
- Additional modes for resistivity, salinity, TDS and mV
- Data logger with auto save/print options
- Storage of up to 500 readings (250 for each mode)
The 3540 is ideal for use in all laboratories where pH and conductivity analyses are required. The setup menu gives quick and easy access to the whole range of instrument, pH and conductivity measurement options. Calibration of both channels is automatic, with the option to select 1, 2 or 3 calibration points. The pH channel can also display mV values if required.The 3540 conductivity pH meter is supplied with a glass combination pH electrode (924 005), glass conductivity probe (K=1 027 013), electrode stand and holder, ATC probe (027 500), BNC shorting plug, pH buffers and US power supply.
Parameter3540
pH range
-2.000 to +20.000
pH resolution
0.001/0.01/0.1
pH accuracy
±0.003
Conductivity range
Auto-selected from 0.01µS to 1.999S
Conductivity resolution
0.01µS to 1mS
Conductivity accuarcy
±0.5% ±2 digits
mV range
±1999.9mV
mV resolution
0.1mV
mV accuracy
±0.2mV
Temperature range
-10 to 105°C
Temperature resolution
0.1°C
Temperature accuracy
±°0.5°C
ATC range
0 to 100°C
Reference temperature
18,20 or 25°C
GLP
Calibration reminder interval,
Security code protected dataOutputs
Analogue, RS232and IrDA
Connector
BNC (pH) and 7-pin DIN (conductivity)
Power
9V AC ±10% @ 50/60Hz
Size (l x w x d)
210 x 250 x 55mm
Weight
850g
Traceable Calibrated Fridge/Freezer Digital Thermometer
Monitor minimum and maximum temperatures— all at a single glance!
Item #: ATC1
- Includes NIST-Traceable certificate from A2LA accredited (1750.01) calibration laboratory
- Triple-display—shows high, low, and current temperature simultaneously
- Features a bottle probe, probe is sealed in a glycol solution
- Min/max memory
- High and low settable alarms
- 1-year warranty
Easily monitor temperature in liquids, baths, air/gas, incubators, refrigerators, or freezers. Keep track of temperature conditions overnight or for any time period—minimum and maximum temperatures are stored until the memory is cleared. Models feature a triple display that simultaneously shows current, minimum, and maximum temperatures. Set high and low alarms in 1° increments; the alarm sounds when temperature rises above or falls below set points, and continues to sound even if temperature returns to nonalarm range. The thermometer reads ambient temperature or probe temperature. The probe is attached to a 10-ft (3 m) micro-cable that permits doors to close on it; the probe and cable are both submersible. Mount the meter with included hook-and-loop strips, and wall-mount slots, or use the flip-open stand on the benchtop.
Model 94460-72 is supplied with a special bottle probe specifically designed for refrigerator/freezer applications. The temperature sensor is enclosed in a bottle, which protects it from rapid temperature changes when the refrigerator door is opened
Guaranteed to have at least one year of calibration remaining on certificate.
Traceable® Products have an individually-numbered Traceable® Certificate provided with each unit.
Specifications
| Meter Measurement Type | Digital Indicator |
| Number Of Probe Channels | 1 |
| Min Temperature (° F) | -58 |
| Max Temperature (° F) | 158 |
| Min Temperature (° C) | -50 |
| Max Temperature (° C)70 | |
| Resolution | 1° |
| AlarmYes | Yes |
| Display Type | 0.75\" Display |
| Height (in) | 4.25 |
| Depth (in) | 0.75 |
| No. of Probe(s) Included | 1 |
| Probe Diameter (in) | 0.1875 |
| Probe Length (in) | 0.875 |
| Battery | 2 AA (included) |
| Description | Calibrated Fridge/Freezer Digital Thermometer; 1 Bottle Probe |
| Warranty | 1 year |