Refrigerators
Reliable Lab Refrigeration Equipment for Sample Safety
Protect your valuable samples and reagents with MIDSCI’s dependable lab refrigeration solutions. Our innovative refrigerators are designed to maintain superior temperature stability while offering durability and energy efficiency for any research or testing environment.
Choose from a wide range of features, including Low-E double-pane thermal glass, digital displays with alarms, and heavy-duty PVC-coated wire shelves for long-lasting performance. Enjoy minimal maintenance with cycle defrost technology, reduce energy costs with ENERGY STAR® efficiency, and support sustainability with CFC-free refrigerants.
Keep your lab organized, efficient, and environmentally friendly with MIDSCI™ refrigeration equipment.
Contact us today to find the perfect refrigerator for your lab, and sign up for our newsletter to hear about upcoming offers!
Premier Glass Door Laboratory Refrigerators
Premier Glass Door Laboratory Refrigerators are engineered to provide precise temperature control, dependable sample protection, and energyefficient performance for laboratory, research, and clinical environments.
Each unit is equipped with a microprocessorbased temperature controller and digital display, delivering superior temperature accuracy, rapid recovery, and reliable verification compared to traditional mechanical thermostats. An interior fandriven, forceddraft air circulation system ensures excellent temperature uniformity throughout the cabinet and quick stabilization after door openings.
To safeguard critical samples, Premier Laboratory Refrigerators include a comprehensive suite of audible and visual alarms that alert users to temperature deviations, power loss, and other critical conditions. The temperature display and alarm module operates independently of the microprocessor temperature controller, providing an added layer of security and reliability.
Premier refrigerators are available in a wide range of sizes and door configurations, with capacities ranging from 10 to 72 cubic feet, allowing laboratories to select the ideal unit for their storage needs.
Designed with sustainability in mind, these refrigerators utilize environmentally friendly natural hydrocarbon (HC) refrigerants that contain no hydrofluorocarbons. This significantly reduces globalwarming potential (GWP) while meeting EPA/SNAP mandates and complying with UL and ASHRAE guidelines.
Main Attributes
- Microprocessor temperature controller with digital display
- Superior temperature accuracy, stability, and recovery
- Fandriven forceddraft air circulation for uniform cooling
- Extensive audible and visual alarm system
- Independent monitoring and alarm module for added security
- Glass door design for easy inventory visibility
- Available in sizes from 10 to 72 cu. ft.
- Environmentally friendly HC refrigerants
- Compliant with EPA/SNAP, UL, and ASHRAE standards
Solid Door Built-In Vaccine Refrigerator
REFRIGERATION SYSTEM
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Standard Laboratory Refrigerator With Natural Refrigerants
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Etl Listed
- Shipping Weight: 200 Lbs.
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module With Battery Back-up to Support Temperature Monitoring and Alarms
- Sample Simulated Digital Temperature Display; .1° Resolution Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back
NEW! Haier solid-door pharmacy refrigerators!
Pre-order now to ensure you get yours.
New models (HYC-85FD, HYC-461FD, HYC-1031FD) will be in stock and available starting November 2024.
Haier Pharmacy Refrigerators
Used for storage of medicines, vaccines, reagents, biological products and other items that require a temperature between 2-8°C. Used in hospitals, pharmacies, pharmaceutical factories, clinics and laboratories etc.
- Energy Efficient: Each unit uses eco-friendly refrigerants: R290 (HYC-1031GD) and R600a (HYC-461GD) and offers low power consumption relative to performance
- Temperature Uniformity: Extends the shelf life of stored items and eliminates inconsistent results
- Insulation: Features polyurethane insulation
- Alarm Functions: Comes with multiple alarm functions, including audible/visual alerts for monitoring, and some include remote alarm contacts
- Cooling System: Uses hermetically sealed compressors and forced-air circulation for efficient cooling. Includes auto defrost
- Security: All models have security features, including a unique-key lock for safe storage
- Accessibility: Adjustable wire shelves are standard across all models to improve circulation and flexible storage
- Display and Controls: Integrated digital control panels with microprocessors are used in all models, allowing for precise temperature control and easy monitoring
- Low Noise Operation: All models are designed for quiet operation (35 – 43 dB(A))
Glass Door Freestanding Vaccine Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
| STABILITY² (CABINET AIR) | +/- 1.3°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.67 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 36 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Solid Door Freestanding Vaccine Refrigerator Certified to NSF/ANSI 456
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, PROPANE |
| CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
| STABILITY² (CABINET AIR) | +/- 1.3°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.5°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.67 KWH/DAY (315 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 42 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Templog Premier Glass Door Chromatography Refrigerator
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°c - 10°c
- Touch Screen Digital Temperature Display and Alarm Module
- Password-protected Control Panel
- Sample Simulated Digital Temperature Display; .1° Resolution, Adjustable Temperature Display in Celsius or Fahrenheit
- Active Temperature Scale Bar Display
- Resettable 1-point Min/max History and Digital 24-hour Temperature Chart Temperature Data Logging
- Usb Port for Data Transfer and Software Updates
- Real-time Operational Display Clock
- 4-20ma Output
- Electronic Troubleshooting Guide
- Electronic Qr Code to Access Owner’s Manual & Technical Support Contact Info Adjustable Alarm Volume
- Audible and Visual High/low Temperature Alarms
ABS Standard Glass Door Laboratory Refrigerators
Standard Glass Door Laboratory Refrigerators deliver reliable, energyefficient cold storage designed specifically for laboratory environments. Built with ultralow energy consumption and natural refrigerants, these refrigerators provide a sustainable solution without compromising performance.
Equipped with microprocessor temperature control, this model ensures precise temperature monitoring and consistent cooling for sensitive samples and reagents. Essential safety features, including a keyed door lock, high- and low-temperature alarms, and remote alarm contacts, help protect valuable laboratory materials.
The durable, powdercoated steel exterior, transparent glass door, and adjustable shelves make organization simple and enhance workflow efficiency. Engineered for long-lasting performance, this refrigerator is ideal for research facilities, clinical labs, pharmaceuticals, and biotech applications.
Disclaimer
Refrigerator requires a minimum 2-inch clearance at the back and sides of unit for proper ventilation.
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R290, PROPANE |
| CONDENSER | FIN AND TUBE DESIGN, HIGH EFFICIENCY FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.0°C |
| STABILITY² (CABINET AIR) | +/- 1.1°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.7°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6.5 MIN. |
| ENERGY CONSUMPTION | 1.32 KWH/DAY |
| AVERAGE HEAT REJECTION | 2.21 KWH/DAY (315 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 49 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 30 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Stainless Steel Built-In Vaccine Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
456 Pharmacy Solid Door Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R290, PROPANE |
| CONDENSER | FIN AND TUBE DESIGN, HIGH EFFICIENCY FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.0°C |
| STABILITY² (CABINET AIR) | +/- 1.1°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.7°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6.5 MIN. |
| ENERGY CONSUMPTION | 1.32 KWH/DAY |
| AVERAGE HEAT REJECTION | 2.21 KWH/DAY (315 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 49 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 30 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Premier Glass Door Chromatography Refrigerator
- Cycle Defrost
- 115v, 60 Hz, 3 Amps, 1/5 Hp
- Shipping Weight: 283 Lbs. Note: This Unit Requires Two (2) Outlets
- Microprocessor Temperature Controller
- Adjustable Operating Temperature Range: 1°-10°c
- Digital Temperature Display and Alarm Module
- Sample Simulated Digital Temperature Display; .1° Resolution
- Adjustable Temperature Display in Celsius or Fahrenheit
- Audible and Visual High/low Temperature Alarms
- Sensor Error Alarm
- Power Failure Alarm
- Resettable 1-point Min/max History
- Remote Alarm Contacts
- 2 Probes; 1 in Air and 1 in Sample Bottle
- Alarm Validation (Audible, Visual, and Remote Alarm)
- Alarm Mute With Ring Back