Solid Door Built-In Vaccine Refrigerator
REFRIGERATION SYSTEM
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Glass Door Freestanding Vaccine Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
| STABILITY² (CABINET AIR) | +/- 1.3°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.67 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 36 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Solid Door Freestanding Vaccine Refrigerator Certified to NSF/ANSI 456
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, PROPANE |
| CONDENSER | TUBE AND GRID CONSTRUCTION, FANLESS |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 1.4°C |
| STABILITY² (CABINET AIR) | +/- 1.3°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.7°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.5°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 6 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.67 KWH/DAY (315 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 41 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 42 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Stainless Steel Built-In Vaccine Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Glass Door Built-in Vaccine Refrigerator
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Built-In Vaccine Refrigerator NSF/ANSI 456 Certified
| COMPRESSOR | HERMETIC, HIGH PERFORMANCE |
| REFRIGERANT | EPA SNAP COMPLIANT, R600A, ISOBUTANE |
| CONDENSER | HYBRID FIN AND TUBE WITH LOW NOISE FAN |
| EVAPORATOR | PLATE WALL |
| DEFROST | CYCLE OPTIMIZED, ZERO ENERGY |
| UNIFORMITY¹ (CABINET AIR) | +/- 0.8°C |
| STABILITY² (CABINET AIR) | +/- 1.2°C |
| MAXIMUM TEMPERATURE VARIATION (CABINET AIR) | +/- 1.4°C |
| TEMPERATURE RISE AFTER AN AFTER 8 SEC DOOR OPENINGS | TEMPERATURE DID NOT EXCEED 6.4°C AT ANY PROBE FOR ALL REQUIRED NSF/ANSI 456 TESTING PROTOCOLS |
| RECOVERY AFTER 3 MIN DOOR OPENING | ALL PROBES RECOVER TO UNDER 8°C WITHIN 4.8 MIN. |
| ENERGY CONSUMPTION | 1.15 KWH/DAY |
| AVERAGE HEAT REJECTION | 1.57 KWH/DAY (224 BTU/H) |
| NOISE PRESSURE LEVEL (DBA) | 43 OR LESS INSTALLED |
| PULL DOWN TIME TO NOMINAL OPERATING TEMP | 35 MIN |
PERFORMANCE DATA ACQUIRED AT 22°C AMBIENT, USING NSF/ANSI 456 COMPLIANT VALIDATION BALLAST PROBES, EMPTY CHAMBER, DURING STABILIZED STEADY STATE OPERATION AND A DAQ SAMPLING RATE OF ONE MEASUREMENT EVERY 10 SECONDS
- UNIFORMITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE ACROSS ALL PROBES AT ANY POINT IN TIME OVER THE TESTING PERIOD
- STABILITY IS DEFINED AS THE MAXIMUM VARIANCE IN TEMPERATURE EXPERIENCED BY ANY SINGLE PROBE OVER THE TESTING PERIOD
- TEMPERATURE PERFORMANCE FOR ALL LOADED AND UNLOADED DOOR OPENING PROTOCOLS, ALL ALARM, CONTROLLER AND PROBE REQUIREMENTS AS DEFINED IN THE NSF/ANSI 456 STANDARD FOR VACCINE STORAGE
- DATA PER ENERGY STAR TEST RESULTS OR EQUIVALENT TESTING AND CALCULATION. HEAT REJECTION BASED ON DAILY AVERAGES, NOT CONTINUOUS OPERATION. PERFORMANCE EXCEEDS ENERGY STAR REQUIREMENTS.
| CONTROLLER TECHNOLOGY | PARAMETRIC, MICROPROCESSOR, LED DISPLAY WITH 0.1°C RESOLUTION |
| TEMPERATURE SETPOINT RANGE | 1°C TO 10°C (SETPOINT MUST REMAIN UNALTERED FROM THE FACTORY SETTING TO REMAIN COMPLIANT WITH NSF/ANSI PERFORMANCE REQUIREMENTS) |
| DISPLAY PROBE | CALIBRATED, STAINLESS STEEL |
| EXTERNAL ALARM CONNECTION | STATE SWITCHING REMOTE ALARM CONTACTS |
| ALARMS | VISUAL AND AUDIBLE INDICATORS |
| HIGH / LOW TEMPERATURE, COMPLIANT WITH ALARM REQUIREMENTS DEFINED IN THE NSF/ANSI STANDARD FOR VACCINE STORAGE | |
| SIMULATOR BALLAST | 20 ML BOTTLE, GLASS BEAD THERMAL MEDIA |
Premier Glass Door Laboratory Refrigerators
Premier Glass Door Laboratory Refrigerators are engineered to provide precise temperature control, dependable sample protection, and energyefficient performance for laboratory, research, and clinical environments.
Each unit is equipped with a microprocessorbased temperature controller and digital display, delivering superior temperature accuracy, rapid recovery, and reliable verification compared to traditional mechanical thermostats. An interior fandriven, forceddraft air circulation system ensures excellent temperature uniformity throughout the cabinet and quick stabilization after door openings.
To safeguard critical samples, Premier Laboratory Refrigerators include a comprehensive suite of audible and visual alarms that alert users to temperature deviations, power loss, and other critical conditions. The temperature display and alarm module operates independently of the microprocessor temperature controller, providing an added layer of security and reliability.
Premier refrigerators are available in a wide range of sizes and door configurations, with capacities ranging from 10 to 72 cubic feet, allowing laboratories to select the ideal unit for their storage needs.
Designed with sustainability in mind, these refrigerators utilize environmentally friendly natural hydrocarbon (HC) refrigerants that contain no hydrofluorocarbons. This significantly reduces globalwarming potential (GWP) while meeting EPA/SNAP mandates and complying with UL and ASHRAE guidelines.
Main Attributes
- Microprocessor temperature controller with digital display
- Superior temperature accuracy, stability, and recovery
- Fandriven forceddraft air circulation for uniform cooling
- Extensive audible and visual alarm system
- Independent monitoring and alarm module for added security
- Glass door design for easy inventory visibility
- Available in sizes from 10 to 72 cu. ft.
- Environmentally friendly HC refrigerants
- Compliant with EPA/SNAP, UL, and ASHRAE standards
PERFORMANCE PHARMACY-VACCINE REFRIGERATORS
Designed and purpose-built for pharmacy, medication, and vaccination applications to support meeting CDC/VFC vaccine storage guidelines.
FEATURING:
- Built-in readout for current and high/low temperature
- Audible and visual high/low temperature alarms
- Optimized efficient performance for stable temperature
- Eco-friendly natural refrigerants for a greener footprint
ADVANCED TEMPERATURE CONTROL
- Intelligent microprocessor digital temperature controller
- Improved temperature accuracy with a buffered probe in glycol-filled bottle to simulate temperature of stored product
- Additional sensor reads interior air temperature for superior temperature control
- Adjustable operating control range from +2°C to +8°C (+35.6°F to +46.4°F)
- Digital display of the min/max temperature (updated in 15 minute increments)
- Temperature viewable in Celsius and Fahrenheit to the nearest tenth of a degree
- Password protection of control parameters beyond setpoint
- Optimized forced air cooling for excellent temperature stability and uniformity with rapid recovery after door openings and product loading
MULTIPLE ALARMS FOR SAFER MONITORING
- Audible/visual alarms for high/low temperature excursions
- Open door alarm sounds if the door is left ajar (default 4 minutes with selectable 1-99 minute range)
- Audible power failure and sensor failure alarms
- Mute function for alarms
- Remote alarm contacts in rear of the unit
FULLY FEATURED INTERIOR FOR CONVENIENT STORAGE
- Energy efficient LED lighting with internal on/off switch
- Adjustable plastic-coated wire shelves for improved circulation
- Multiple shelf positions spaced at ½ to allow flexible adjusting to support smaller items
- Adjustable cycle defrost operation
- probe port included to accept user-provided monitoring equipment
QUALITY DESIGN FOR RELIABLE PERFORMANCE
- Self-closing door offers added storage protection
- User-reversible door swing (self-closing function compatible with RHD position only)
- Environmentally-friendly natural hydrocarbon refrigerant for reduced global warming potential
- Meets EPA and SNAP requirements
- Convenient security with a top-mounted door lock (2 keys included)
- Magnetic gaskets to ensure a positive seal
- Pyxis®, Omnicell® and AcuDose RX® compatible
TECHNICAL SPECIFICIATIONS:
Model |
Capacity |
Height [in] |
Width [in] |
Depth [in] |
Door |
Cabinet |
Shelves |
Internal Fans |
ARS1PV |
1 Cu. Ft. |
21.5 |
17.5 |
19.5 |
White |
White |
3 |
1 |
ARG1PV |
1 Cu. Ft. |
21.5 |
17.5 |
20 |
Glass |
White |
3 |
1 |
ARS3PV |
3 Cu. Ft. |
33.75 |
18.5 |
19 |
White |
White |
4 |
1 |
ARG3PV |
3 Cu. Ft. |
33.75 |
18.5 |
19.5 |
Glass |
White |
4 |
1 |
ARS6PV |
6 Cu. Ft. |
32.5 |
23.5 |
24.5 |
White |
White |
4 |
1 |
ARG6PV |
6 Cu. Ft. |
32.5 |
23.5 |
25 |
Glass |
White |
4 |
1 |
ARS8PV |
8 Cu. Ft. |
50 |
23.38 |
24.5 |
White |
White |
7 |
2 |
ARG8PV |
8 Cu. Ft. |
50 |
23.38 |
25 |
Glass |
White |
7 |
2 |
ARS12PV |
12 Cu. Ft. |
61.75 |
23.38 |
24.5 |
White |
White |
7 |
2 |
ARG12PV |
12 Cu. Ft. |
61.75 |
23.38 |
25 |
Glass |
White |
7 |
2 |
ARS15PV |
15 Cu. Ft. |
72 |
23.5 |
24.5 |
White |
White |
7 |
2 |
ARG15PV |
15 Cu. Ft. |
72 |
23.5 |
25 |
Glass |
White |
7 |
2 |
TECHNICAL SPECIFICATIONS (ALL UNITS):
- Defrost: Cycle
- Thermostat: Intelligent microprocessor digital
- Temperature Sensors: 2 (air probe and buffered probe)
- Adjustable Operating Control Range: 2°C to +8°C (+35.6°F to +46.4°F)
- Preset: 5ºC/41ºF
- Temperature Variation: +/-1°C
- Shelving: White plastic coated wire
- Voltage: 115V/60Hz
- Cord: NEMA 5-15P
- Lock: Factory-installed key lock
- Refrigerant: Eco-friendly R600a
- Light: LED
- Access Port:
- Door: Reversible
- Fan: Internal
- Certifications: ETL, ETL-C
- Parts & Labor Warranty: 2 years
- Compressor Warranty: 5 years
INCLUDED
- DO NOT UNPLUG warning sticker
- DO NOT ADJUST TEMPERATURE warning sticker
- DO NOT STORE PERSONAL ITEMS warning sticker
OPTIONS
- NIST calibrated temperature readout with 2-year certificate of conformity
- Digital data logger (DDL) installed or as kit with 2-year certificate of conformity
PERFORMANCE PHARMACY-VACCINE REFRIGERATORS
Designed and purpose-built for pharmacy, medication, and vaccination applications to support meeting CDC/VFC vaccine storage guidelines.
FEATURING:
- Built-in readout for current and high/low temperature
- Audible and visual high/low temperature alarms
- Optimized efficient performance for stable temperature
- Eco-friendly natural refrigerants for a greener footprint
ADVANCED TEMPERATURE CONTROL
- Intelligent microprocessor digital temperature controller
- Improved temperature accuracy with a buffered probe in glycol-filled bottle to simulate temperature of stored product
- Additional sensor reads interior air temperature for superior temperature control
- Adjustable operating control range from +2°C to +8°C (+35.6°F to +46.4°F)
- Digital display of the min/max temperature (updated in 15 minute increments)
- Temperature viewable in Celsius and Fahrenheit to the nearest tenth of a degree
- Password protection of control parameters beyond setpoint
- Optimized forced air cooling for excellent temperature stability and uniformity with rapid recovery after door openings and product loading
MULTIPLE ALARMS FOR SAFER MONITORING
- Audible/visual alarms for high/low temperature excursions
- Open door alarm sounds if the door is left ajar (default 4 minutes with selectable 1-99 minute range)
- Audible power failure and sensor failure alarms
- Mute function for alarms
- Remote alarm contacts in rear of the unit
FULLY FEATURED INTERIOR FOR CONVENIENT STORAGE
- Energy efficient LED lighting with internal on/off switch
- Adjustable plastic-coated wire shelves for improved circulation
- Multiple shelf positions spaced at ½ to allow flexible adjusting to support smaller items
- Adjustable cycle defrost operation
- probe port included to accept user-provided monitoring equipment
QUALITY DESIGN FOR RELIABLE PERFORMANCE
- Self-closing door offers added storage protection
- User-reversible door swing (self-closing function compatible with RHD position only)
- Environmentally-friendly natural hydrocarbon refrigerant for reduced global warming potential
- Meets EPA and SNAP requirements
- Convenient security with a top-mounted door lock (2 keys included)
- Magnetic gaskets to ensure a positive seal
- Pyxis®, Omnicell® and AcuDose RX® compatible
TECHNICAL SPECIFICIATIONS:
Model |
Capacity |
Height [in] |
Width [in] |
Depth [in] |
Door |
Cabinet |
Shelves |
Internal Fans |
ARS1PV |
1 Cu. Ft. |
21.5 |
17.5 |
19.5 |
White |
White |
3 |
1 |
ARG1PV |
1 Cu. Ft. |
21.5 |
17.5 |
20 |
Glass |
White |
3 |
1 |
ARS3PV |
3 Cu. Ft. |
33.75 |
18.5 |
19 |
White |
White |
4 |
1 |
ARG3PV |
3 Cu. Ft. |
33.75 |
18.5 |
19.5 |
Glass |
White |
4 |
1 |
ARS6PV |
6 Cu. Ft. |
32.5 |
23.5 |
24.5 |
White |
White |
4 |
1 |
ARG6PV |
6 Cu. Ft. |
32.5 |
23.5 |
25 |
Glass |
White |
4 |
1 |
ARS8PV |
8 Cu. Ft. |
50 |
23.38 |
24.5 |
White |
White |
7 |
2 |
ARG8PV |
8 Cu. Ft. |
50 |
23.38 |
25 |
Glass |
White |
7 |
2 |
ARS12PV |
12 Cu. Ft. |
61.75 |
23.38 |
24.5 |
White |
White |
7 |
2 |
ARG12PV |
12 Cu. Ft. |
61.75 |
23.38 |
25 |
Glass |
White |
7 |
2 |
ARS15PV |
15 Cu. Ft. |
72 |
23.5 |
24.5 |
White |
White |
7 |
2 |
ARG15PV |
15 Cu. Ft. |
72 |
23.5 |
25 |
Glass |
White |
7 |
2 |
TECHNICAL SPECIFICATIONS (ALL UNITS):
- Defrost: Cycle
- Thermostat: Intelligent microprocessor digital
- Temperature Sensors: 2 (air probe and buffered probe)
- Adjustable Operating Control Range: 2°C to +8°C (+35.6°F to +46.4°F)
- Preset: 5ºC/41ºF
- Temperature Variation: +/-1°C
- Shelving: White plastic coated wire
- Voltage: 115V/60Hz
- Cord: NEMA 5-15P
- Lock: Factory-installed key lock
- Refrigerant: Eco-friendly R600a
- Light: LED
- Access Port:
- Door: Reversible
- Fan: Internal
- Certifications: ETL, ETL-C
- Parts & Labor Warranty: 2 years
- Compressor Warranty: 5 years
INCLUDED
- DO NOT UNPLUG warning sticker
- DO NOT ADJUST TEMPERATURE warning sticker
- DO NOT STORE PERSONAL ITEMS warning sticker
OPTIONS
- NIST calibrated temperature readout with 2-year certificate of conformity
- Digital data logger (DDL) installed or as kit with 2-year certificate of conformity