For pricing, please Request a Quote above!!

NanoPhotometer™ Pearl Design Edition - Small. Fast. Accurate.

NanoPhotometer™ Pearl Design Edition UV/VIS spectrophotometer for Nano Volume and standard cuvette applications with built-in computer, touch pad, thermal paper printer, USB port for data transfer, NanoPhotometer™ Pearl Software Package, cables and manual. (Software Sold Separately)


The NanoPhotometer™ Pearl combines ultra low (0.3µl) and standard volume cuvette applications for improved concentration measurement and purity analysis in one UV/Vis spectrophotometer The NanoPhotometer™ Pearl is a maintenance free and stand alone device with flexible data output options, bringing portability, convenience, and speed to UV/Vis spectrophotometry. Applications are limitless with full scanning (200-950nm), superior sample stability, and programmable methods to suit your needs. The NanoPhotometer™ Pearl Design Edition comes with lid factor 10 and 50.

Product Features:

pdf Average Detection Range for Nucleic Acids and Proteins

 

Product Specifications:

SPECTROMODULE


Wavelength range

 

190 - 1,100 nm

Wavelength scan range

200 - 950 nm

System start up time

Less than 5 seconds, no warm up necessary

Measure time for full scan range    

3.5 seconds

Wavelength reproducibility

< ± 0.2 nm

Wavelength accuracy

± 2nm

Bandwidth

Better than 5nm

Stray light

<0.5% at 220 nm using NaI and 340 nm using NaNO2

Photometric range

-0.3 - 2.499 A 0-199% T

Detection Range

dsDNA: 0.5 ng / µl to 125 ng / µl, BSA: 0.02 mg / ml to 3.6 mg / ml

Absorbance reproducibility

±0.003 A (0 to 0.5 A), ±0.007 A (0.5-1.0 A) @ 260 nm

Absorbance accuracy

±0.005 A or ±1% of the reading, whichever is the greater

Zero stability

±0.003 A/hour after 20 min warm up @ 340 nm

Noise

0.002 A rms at 0 A @ 260 nm
0.005 A (pk to pk) at 0 A @ 260 nm

Optical arrangement

Dual channel Czerny Turner with flat grating, 1024 pixel CCD array, concave mirrors

Lamp

Xenon flash lamp

Lifetime

10⁹ flashes, up to 10 years

Cell types

15 mm centre height (z-height), outside dimension 12.5 mm x 12.5 mm

SMALL VOLUME OPTION


Detection range

 

dsDNA: 2 ng/µl to 18,750 ng/µl, BSA: 0.08 mg/ml to 543 mg/ml

Absorbance range

0.01 - 1.5 (10 mm equivalent: 0.05 - 375)

Minimum sample size

0.3 µl

Path lengths

0.04 mm, 0.1 mm, 0.2 mm, 1 mm and 2 mm

Virtual dilution factors

5, 10, 50, 100 and 250

OTHER TECHNICAL DATA


Cuvette storage

 

capacity for eight 10 mm cells

Photometric mode

Abs, %T, concentration, scan, ratio, multi wavelength, kinetics in Abs x factor / min

Method storage

Up to 81 methods in user methods

Built-in methods

Nucleic acid, microarray (labeling efficiency), protein and cell density

Display formats

320 x 240 pixels

Size

140 mm x 275 mm x 380 mm

Weight

< 4.5 kg

Operating voltage

90-250 V, 50/60 Hz, Max 30 VA

Input / Output ports

SD Memory Card, USB or Bluetooth for connection to a PC for direct data download, printout and data storage

Performance verification

Auto diagnostics when switched on

Warranty

1 year